无法使分区驱动器'原因:未找到磁盘'出现故障。
适用场景
- ONTAP 9
- ADP (高级驱动器分区)
问题描述
- 销毁聚合后无法取消驱动器分区
- 容器状态显示正常/运行状况良好、但分区显示为已断开
Cluster::*> disk partition show
Usable Container Container
Partition Size Type Name Owner
------------------------- ------- ------------- ----------------- -----------------
1.0.0.P1 1.72TB broken - Node-01
1.0.0.P2 1.72TB broken - Node-01
1.0.0.P3 62.35GB broken - Node-01
1.0.1.P1 1.72TB broken - Node-01
1.0.1.P2 1.72TB broken - Node-01
1.0.1.P3 62.35GB broken - Node-01
- 无法从集群Shell和节点Shell使驱动器出现故障或使其失效
::> storage disk unfail -disk 1.0.0 -spare true
Warning: Failed disk "1.0.0" might have aggregate labels and file system data present. Releasing this disk as a spare disk will lead to permanent loss of file system data that might be on this disk, and it might prevent recovery of a failed aggregate. Are you sure you want tocontinue with disk unfail {y|n}: y
Error: command failed: Failed to unfail the disk. Reason: Disk not found.