跳转到主内容

更换主板后无法切回

Views:
11
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009345870</a>
Specialty:
MetroCluster
Last Updated:

适用场景

  • AFF 和FAS
  • ONTAP 9
  • 双节点延伸型 MetroCluster

问题描述

  • 完成主板更换后无法执行切回:
 
clusterA::> metrocluster switchback -simulate [Job 001] Setting up the node and cluster components for the switchback operation...[Job 001] Job failed: Failed to set up the node and cluster components for the switchback operation. Use the "metrocluster operation show" command to view detailed error information. Resolve the errors, then try the command again.
clusterA::> metrocluster operation show Operation: switchback-simulate State: failed Start Time: 10/27/2022 11:34:27 End Time: 10/27/2022 11:35:09 Errors: Failed to set up the node and cluster components for the switchback operation. clusterA (fatal): Configuration replication service is not ready in cluster "clusterB". Wait a few minutes, then try the command again.
 
  • 受损节点无法识别其正在切换:
 
clusterB::> metrocluster show
Configuration: stretch
Cluster Entry Name State ------------------------------ ---------------------- --------------------- Local: clusterB Configuration State configured Mode normal AUSO Failure Domain auso-on-cluster-disaster Remote: clusterA Configuration State configured Mode switchover AUSO Failure Domain auso-on-cluster-disaster
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.