更换主板后无法切回
- Views:
- 11
- Visibility:
- Public
- Votes:
- 0
- Category:
- fas-systems<a>2009345870</a>
- Specialty:
- MetroCluster
- Last Updated:
适用场景
- AFF 和FAS
- ONTAP 9
- 双节点延伸型 MetroCluster
问题描述
- 完成主板更换后无法执行切回:
clusterA::> metrocluster switchback -simulate [Job 001] Setting up the node and cluster components for the switchback operation...[Job 001] Job failed: Failed to set up the node and cluster components for the switchback operation. Use the "metrocluster operation show" command to view detailed error information. Resolve the errors, then try the command again.
clusterA::> metrocluster operation show Operation: switchback-simulate State: failed Start Time: 10/27/2022 11:34:27 End Time: 10/27/2022 11:35:09 Errors: Failed to set up the node and cluster components for the switchback operation. clusterA (fatal): Configuration replication service is not ready in cluster "clusterB". Wait a few minutes, then try the command again.
- 受损节点无法识别其正在切换:
clusterB::> metrocluster show
Configuration: stretch
Cluster Entry Name State ------------------------------ ---------------------- --------------------- Local: clusterB Configuration State configured Mode normal AUSO Failure Domain auso-on-cluster-disaster Remote: clusterA Configuration State configured Mode switchover AUSO Failure Domain auso-on-cluster-disaster