温度传感器出现“无法恢复”警告
适用场景
- ONTAP 9
- FAS/AFA
- DS224
- DS212
问题描述
- 从中可以看到以下错误
EMS logs
。
[NODE A: dsa_worker0: ses.status.temperatureError:error]: DS224-12 (S/N 123456708) shelf 0 on channel 0b temperature error for Temperature sensor 1: internal communication error. Current temperature: 20 C (68 F). This module is on the front of the shelf on the left, on the OPS panel.
[NODE A: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
[NODE A: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
或者可能会自动恢复
[monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
[tatd: monitor.shelf.fault.ok:notice]: Fault previously reported on disk storage shelf attached to channel 0b has been corrected.
[monitor: monitor.globalStatus.ok:notice]: The system's global status is normal.
- 传感器状态可以看作
UNRECOVERABLE
在Storage fault
日志。
Enclosure Status: unrecoverable
Channel: 0b
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: SHFGB2026000259
Module Type: IOM12E
Temperature Sensors:
Element Status Status Bytes Status Descriptions
1: UNRECOVERABLE 04,00,28,00
2: OK 01,00,2C,00
3: OK 01,00,2C,00
4: OK 01,00,2B,00