对于HA配对系统中的一个文件管理器、4端口SAS HBA卡上的两个端口未显示在autoc횧 돖 或Sysconfig -A输出中
适用场景
- AFF 和 FAS
- Data ONTAP 8.
- ONTAP 9
- host bus adapter(主机总线适配器)(HBA)
问题描述
sysconfig -a
命令仅显示卡上四个可用端口中的两个、sysconfig -a
类似于以下输出:
slot 4: SAS Host Adapter 4a
PMC-Sierra PM8001 rev. C, SAS, ) MFG Part Number: USI 6086-000010-06 rev. MP V4.9 Part number: 111-00341+F1
Serial number: ST062CB102Z Date Code: 20121101 Firmware rev: 01.11.00.00 Base WWN: 5:00e004:000233a:08
Phy State: [0] Enabled, 6.0 Gb/s [1] Enabled, 6.0 Gb/s [2] Enabled, 6.0 Gb/s [3] Enabled, 6.0 Gb/s QSFP Vendor: Molex Inc.
QSFP Part Number: 112-00176+A0 QSFP Type: Passive Copper 0.5m ID:01 QSFP Serial Number: 128720476 (Lists disk drives on this adapter)
slot 4: SAS Host Adapter 4b
(PMC-Sierra PM8001 rev. C, SAS, ) MFG Part Number: USI 6086-000010-06 rev. MP V4.9 Part number: 111-00341+F1
Serial number: ST062CB102Z Date Code: 20121101 Firmware rev: 01.11.00.00 Base WWN: 5:00e004:000233a:0c
Phy State: [4] Disabled [5] Disabled [6] Disabled [7] Disabled QSFP Vendor: not available
QSFP Part Number: not available QSFP Type: not available QSFP Serial Number: not available
memory mapped I/O base 0xdf330000, size 0x10000 memory mapped I/O base 0xdf320000, size 0x10000 memory mapped I/O base 0x00000000df310000,
size 0x10000 memory mapped I/O base 0x00000000df300000, size 0x10000 (Lists disk drives on this adapter)
- 因此、输出未显示此存储系统上的端口4c和4d;但是、配对存储系统会准确显示所有四个端口。