跳转到主内容

重建无法在RAID组中启动:备用池中没有匹配的磁盘、目标为Pool1

Views:
29
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

适用场景

FAS8200

问题描述

  • 磁盘出现故障后、即使池0具有备用磁盘、磁盘重建也不会启动:

Fri Aug 19 06:06:27 JST [Nodename-01: config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 1, Bay 9, Model [X341_TA14E900A10], S/N [XXXXXXXXXXXX]
Fri Aug 19 06:06:27 JST [Nodename-01: config_thread: raid.rg.recons.missing:notice]: RAID group /aggr01/plex4/rg0 is missing 1 disk(s).
Fri Aug 19 06:06:27 JST [Nodename-01: config_thread: raid.rg.recons.cantStart:error]: The reconstruction cannot start in RAID group /aggr01/plex4/rg0: No matching disks available in spare pool, targeting Pool1

Pool1 spare disks (empty)

Pool0 spare disks

RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
---------   ------     ------------- ---- ---- ---- ----- --------------    --------------
Spare disks for block checksum
spare     0d.01.9    0d    1   9   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768

  • 配置同步镜像后、目标磁盘位于aggr01的Plex4中、Plex4从池0生成:

Aggregate aggr01 (online, raid_dp, degraded, mirrored) (block checksums)
  Plex /aggr01/plex0 (online, normal, active, pool0)
    RAID group /aggr01/plex0/rg0 (normal, block checksums)

      RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------   ------     ------------- ---- ---- ---- ----- --------------    --------------
      dparity    0a.00.3    0a    0   3   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768
      parity     0a.00.4    0a    0   4   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0a.00.5    0a    0   5   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0a.00.6    0a    0   6   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0a.00.7    0a    0   7   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0a.00.8    0a    0   8   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0a.00.9    0a    0   9   SA:A   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0a.00.10   0a    0   10  SA:A   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0a.00.11   0a    0   11  SA:A   0   SAS 10000 857000/1755136000 858483/1758174768

 Plex /aggr01/plex4 (online, normal, active, pool0)
    RAID group /aggr01/plex4/rg0 (degraded, block checksums)

      RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      ---------   ------     ------------- ---- ---- ---- ----- --------------    --------------
      dparity    0d.01.11   0d    1   11  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
      parity     0d.01.10   0d    1   10  SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0d.01.3    0d    1   3   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0d.01.4    0d    1   4   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0d.01.5    0d    1   5   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0d.01.6    0d    1   6   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0d.01.7    0d    1   7   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
      data      0d.01.8    0d    1   8   SA:B   0   SAS 10000 857000/1755136000 858483/1758174768
     data   FAILED        N/A                        857000/ -

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.