跳转到主内容

FAS8300 系统中意外断电触发接管

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

FAS8300

问题描述

  • 观察到两个意外的系统重新启动。
  • 在第一次重新启动期间,系统恢复,并且回馈成功。
  • 在第一次重新启动期间,BMC 日志中没有明显的硬件故障信息或死机信息。
  • 控制器报告同时失去了两个电源(PSU1 和 PSU2)的直流电源,导致节点自动重新启动并触发接管。

BMC console log
Entity Presence PSU1_VIN_TYPE_DC | Absent | Asserted
Entity Presence PSU2_VIN_TYPE_DC | Absent | Asserted
System Firmware Progress | Secondary CPU Initialization | Asserted
System Firmware Progress | USB resource configuration | Asserted
System Firmware Progress | PCI resource configuration | Asserted
System Firmware Progress | Video initialization | Asserted
System Firmware Progress | Keyboard controller initialization | Asserted
System Firmware Progress | Hard-disk initialization | Asserted
System Firmware Progress | Hard-disk initialization | Asserted
System Event |  | Asserted

  • 在第二次重新启动期间,即使在电源重新启动后,系统也无法开机(system power off/on)。
  • 系统电源状态仍为"Host power is off" 
    通过 BMC 发出的命令(例如 system power onsystem console)未得到响应。

BMC Log:

BMC > system power status
Host power is off
BMC > system power off
Current power is off, no action is taken
BMC  system power status
Host power is off
BMC >system power on
BMC > system console
 →Pressing the enter key gives no output.
BMC > system power status
Host power is off
BMC >

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.