跳转到主内容

在AFF A400、FAS8700、FAS8300上的配对节点未检测到检测信号后接管

Views:
5
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

适用场景

  • ONTAP 9
  • AFF A400
  • FAS8700
  • FAS8300

问题描述

  • 节点意外关闭
  • 合作伙伴节点报告由于丢失心跳而进行的接管:

[Node-02: kltp: clam.heartbeat.state.change:info]: Heartbeats to node (name=Node-01, ID=1000) are Failing.
[Node-02: cf_main: cf.fsm.takeover.noHeartbeat:alert]: Failover monitor: Takeover initiated after no heartbeat was detected from the partner node.

  • BMC 的事件日志报告以下内容:

 b8b | 03/19/2024 | 13:00:38 | Battery Learning #0xc4 | In progress | Asserted
 b8c | 03/19/2024 | 17:14:26 | System Event #0xff | Timestamp Clock Sync | Asserted
 b8d | 03/19/2024 | 17:14:29 | System Event #0xff | Timestamp Clock Sync | Asserted
 b8e | 03/20/2024 | 00:36:49 | Battery Learning #0xc4 | In progress | Asserted
 b8f | 03/20/2024 | 06:38:09 | Power Unit #0xb2 | Power on | Asserted | from channel 1
 b90 | 03/20/2024 | 06:40:34 | Watchdog 2 #0xb1 | Timer expired (OEM) | Asserted
 b91 | 03/20/2024 | 06:41:08 | Power Unit #0xb2 | Power on | Asserted | from channel 1
 b92 | 03/20/2024 | 06:42:45 | Watchdog 2 #0xb1 | Timer expired (OEM) | Asserted
 b93 | 03/20/2024 | 06:44:54 | Watchdog 2 #0xb1 | Timer expired (OEM) | Asserted
 b94 | 03/20/2024 | 07:11:18 | Power Unit #0xb2 | Power on | Asserted | from channel 1
 b95 | 03/20/2024 | 07:13:44 | Watchdog 2 #0xb1 | Timer expired (OEM) | Asserted
 b96 | 03/20/2024 | 07:15:54 | Watchdog 2 #0xb1 | Timer expired (OEM) | Asserted

  • 主板重新安装后节点仍然关闭 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.