系统报告带交换机连接的 NS224 混合路径 HA 磁盘架
适用于
- ONTAP 9
- NS224
- 交换机连接
问题描述
- 热添加附加的交换机连接 NS224 盘架节点后报告混合路径 HA 和磁盘冗余失败
- 在 sysconfig输出中没有丢失磁盘
- 没有与丢失磁盘相关的存储故障或运行状况警报
- AutoSupport disk-path输出报告仅通过一个NSM模块可见的磁盘
- storage disk show -p也仅通过一个NSM可见
问题发生后,可以在 ASUP 的 STORAGE-SHELF 部分观察到以下输出:
================================== Shelf name: 0x.shelf17 Shelf id: 17 Channel: 0x Module: B ★ Shelf UID: 00:a0:98:00:00:57:c9:b9 Shelf S/N: 95240000000000 Term switch: N/A Shelf state: ONLINE Module state: OK Device Port Negotiated Medium Device Port Negotiated Received Disk Port Max Link Max Link Link Max Link Max Lane Max Lane Lane Error Bad TLP Bad DLLP Uncorrectable Correctable Id State Speed Speed Speed Speed Width width width Count Count Count Errors Errors (GT/s) (GT/s) (GT/s) (GT/s) ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ [ 0] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 1] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 2] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 3] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 4] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 5] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 6] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 7] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 8] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 9] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 10] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 11] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 12] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 13] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 14] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 15] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 16] OK 8.0 8.0 8.0 8.0 2 2 2 0 0 0 0 0 [ 17] DIS/DLL NA 8.0 2.5 8.0 0 2 0 0 0 0 0 8192 ★ ==================================