跳转到主内容

在 NV 电池正在学习周期期间,系统故障 LED 亮起

Views:
22
Visibility:
Public
Votes:
0
Category:
aff-series<a>硬件</a><a>NVMEM电池</a><a>服务处理器(SP)</a><a>2008884691</a>
Specialty:
HW
Last Updated:

适用场景

  • A700
  • FAS9000
  • 服务处理器 (SP)

问题描述

  • 在NV电池处于学习周期时、ONTAP 会报告服务事件 Failed reading sensor: 87
  • 系统故障 LED 亮起。
A700::*> system controller service-event show -instance
Node: A700-02
Service Event ID: 1
Location: NV Battery on Controller B
Description: Failed reading sensor: 87
Timestamp: Fri Aug 20 03:23:53 2021

 
Record 124: Fri Aug 20 01:53:36.319800 2021 [IPMI.notice]: f400 | 02 | EVT: 6f08ffff | Bat_Status | Assertion Event, "Learn Cycle"
Record 125: Fri Aug 20 02:49:02.944878 2021 [IPMI.notice]: f500 | c0 | OEM: f9ff7020ff59 | ManufId: 150300 | Undefined
Record 126: Fri Aug 20 03:24:00.265129 2021 [IPMI.notice]: f600 | 02 | EVT: 6f02ffff | PCM_Status | Assertion Event, "Fault"
Record 127: Fri Aug 20 03:24:04.490203 2021 [IPMI.notice]: f700 | 02 | EVT: 6f02ffff | Bat_Status | Assertion Event, "Fault"
Record 128: Fri Aug 20 05:13:48.589136 2021 [IPMI.notice]: f800 | 02 | EVT: ef02ffff | PCM_Status | Deassertion Event, "Fault"
Record 129: Fri Aug 20 05:13:52.483000 2021 [IPMI.notice]: f900 | 02 | EVT: ef02ffff | Bat_Status | Deassertion Event, "Fault"
Record 130: Fri Aug 20 05:49:41.577860 2021 [SP CLI.notice]: admin "log in from Serial Console"
Record 131: Fri Aug 20 05:52:20.645759 2021 [SP CLI.notice]: admin "system battery show "
Record 132: Fri Aug 20 05:54:08.355322 2021 [SP CLI.notice]: admin "system fru show "
Record 133: Fri Aug 20 05:54:17.291095 2021 [SP CLI.notice]: admin "system fru show * "
Record 134: Fri Aug 20 05:54:29.369730 2021 [SP CLI.notice]: admin "system fru list "
Record 135: Fri Aug 20 05:54:40.770936 2021 [SP CLI.notice]: admin "log out"
Record 136: Fri Aug 20 06:58:40.790652 2021 [IPMI.notice]: fa00 | 02 | EVT: ef08ffff | Bat_Status | Deassertion Event, "Learn Cycle

 
  • NV 电池完成学习周期后,此服务事件将消失。
  • 系统故障 LED 熄灭
A700::*> system controller service-event show
This table is currently empty.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.