系统存储配置:由于电缆损坏,混合路径
适用场景
问题描述
- 系统存储配置显示
Mixed-path
在sysconfig -a
输出中。 system health alert show
报告相同
::> system health alert show
Node: node01
Resource: Shelf 4.11
Severity: Major
Indication Time: Tue Jan 30 21:00:54 2024
Suppress: false
Acknowledge: false
Probable Cause: Controller JC8FAS02-03 has only a single-path configuration to disk shelf 4.11. This might occur when the controller does not have dual-path
configuration to stack 4, a SAS HBA port on the controller connected to the disk shelf is disabled, or shelf-to-shelf cabling is incorrect.
- EMS日志:
Fri Apr 07 15:26:37 [node01:dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
Fri Apr 07 15:26:37 [node01:dsa_disc: shelf.config.mixedha:notice]: System is using a mixture of single path, multi-path or quad-path HA storage configurations.
Fri Apr 07 15:26:29 [node02: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
Fri Apr 07 15:26:29 [node02: dsa_disc: shelf.config.mixedha:notice]: System is using a mixture of single path, multi-path or quad-path HA storage configurations.
- IOM模块上的故障LED指示灯均不亮。
- 通过
system node run -node {nodename|local} -command sasadmin expander_map
从控制台运行""命令或在ASUP中检查"sas-expander-map"来检查磁盘架路径。
node01: 端口0c 通过IOM A连接到磁盘架10/11/12 (磁盘架13/14缺失)、端口2d 通过IOM B连接到磁盘架14/13/12/11/10
Expanders on channel 0c:
Level 1: WWN 500a098008657ca9, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A ', Rev '0300', Slot A
Level 2: WWN 500a098008657cb9, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A ', Rev '0300', Slot A
Level 3: WWN 500a09800865817d, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A ', Rev '0300', Slot A
Expanders on channel 2d:
Level 1: WWN 500a098008658569, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 2: WWN 500a098008658415, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 3: WWN 500a098008657ea5, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 4: WWN 500a098008657b35, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 5: WWN 500a098008657c95, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A ', Rev '0300', Slot B
node02: 端口0c 通过IOM B连接到磁盘架10/11/12/13/14、端口2d 通过IOM A连接到磁盘架14/13 (磁盘架12/11/10缺失)。
Expanders on channel 0c:
Level 1: WWN 500a098008657c95, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 2: WWN 500a098008657b35, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 3: WWN 500a098008657ea5, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 4: WWN 500a098008658415, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A ', Rev '0300', Slot B
Level 5: WWN 500a098008658569, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A ', Rev '0300', Slot B
Expanders on channel 2d:
Level 1: WWN 500a098008658585, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A ', Rev '0300', Slot A
Level 2: WWN 500a098008658511, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A ', Rev '0300', Slot A