跳转到主内容

系统存储配置:由于电缆损坏,混合路径

Views:
20
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

ONTAP 9

问题描述

  • 系统存储配置显示 Mixed-path sysconfig -a 输出中。
  • system health alert show 报告相同

::> system health alert show

Node: node01
Resource: Shelf 4.11
Severity: Major
Indication Time: Tue Jan 30 21:00:54 2024
Suppress: false
Acknowledge: false
Probable Cause: Controller JC8FAS02-03 has only a single-path configuration to disk shelf 4.11. This might occur when the controller does not have dual-path
configuration to stack 4, a SAS HBA port on the controller connected to the disk shelf is disabled, or shelf-to-shelf cabling is incorrect.

  • EMS日志:

Fri Apr 07 15:26:37 [node01:dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
Fri Apr 07 15:26:37 [node01:dsa_disc: shelf.config.mixedha:notice]: System is using a mixture of single path, multi-path or quad-path HA storage configurations.
Fri Apr 07 15:26:29 [node02: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
Fri Apr 07 15:26:29 [node02: dsa_disc: shelf.config.mixedha:notice]: System is using a mixture of single path, multi-path or quad-path HA storage configurations.

  • IOM模块上的故障LED指示灯均不亮。
  • 通过system node run -node {nodename|local} -command sasadmin expander_map从控制台运行""命令或在ASUP中检查"sas-expander-map"来检查磁盘架路径。

node01: 端口0c  通过IOM A连接到磁盘架10/11/12 (磁盘架13/14缺失)、端口2d 通过IOM B连接到磁盘架14/13/12/11/10 

Expanders on channel 0c: 
Level   1: WWN 500a098008657ca9, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A  ', Rev '0300', Slot A
Level   2: WWN 500a098008657cb9, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A  ', Rev '0300', Slot A
Level   3: WWN 500a09800865817d, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A  ', Rev '0300', Slot A

Expanders on channel 2d: 
Level   1: WWN 500a098008658569, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level   2: WWN 500a098008658415, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level   3: WWN 500a098008657ea5, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level   4: WWN 500a098008657b35, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level   5: WWN 500a098008657c95, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A  ', Rev '0300', Slot B

node02: 端口0c 通过IOM B连接到磁盘架10/11/12/13/14、端口2d 通过IOM A连接到磁盘架14/13 (磁盘架12/11/10缺失)。 

Expanders on channel 0c: 
Level   1: WWN 500a098008657c95, ID 10, Serial Number ' SHJSG2234000411', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level   2: WWN 500a098008657b35, ID 11, Serial Number ' SHJSG2234000394', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level   3: WWN 500a098008657ea5, ID 12, Serial Number ' SHJSG2234000050', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level   4: WWN 500a098008658415, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A  ', Rev '0300', Slot B
Level   5: WWN 500a098008658569, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A  ', Rev '0300', Slot B

Expanders on channel 2d: 
Level   1: WWN 500a098008658585, ID 14, Serial Number ' SHJSG2234000373', Product 'DS22412IOM12A  ', Rev '0300', Slot A
Level   2: WWN 500a098008658511, ID 13, Serial Number ' SHJSG2234000381', Product 'DS22412IOM12A  ', Rev '0300', Slot A

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?