群集端口关闭导致意外重启
适用于
- AFF A400
- FAS8300
- ONTAP 9
- 无交换机集群
问题描述
- Ems-log显示集群端口关闭
 [Node1: kernel: netif.linkDown:info]: Ethernet e3a: Link down, check cable. [Node1: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node1, port e3a. [Node1: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e3a on node Node1 has gone down unexpectedly. [Node2: kernel: netif.linkDown:info]: Ethernet e3b: Link down, check cable. [Node2: vifmgr: vifmgr.portdown:notice]: A link down event was received on node Node2, port e3b. [Node2: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e3b on node Node2 has gone down unexpectedly.- 接管的原因是错过了心跳
 [
 Node1: cf_main: cf.fsm.takeoverCountdown:info]: Failover monitor: takeover scheduled in 10 seconds[Node1: cf_main: cf.fsm.takeover.noHeartbeat:alert]: Failover monitor: Takeover initiated after no heartbeat was detected from the partner node.[Node1: cf_main: cf.fsm.stateTransit:info]: Failover monitor: UP --> TAKEOVER[Node1: cf_takeover: ha.takeover.stateChng:debug]: params: {'old_state': 'NOT_IN_TAKEOVER', 'new_state': 'IN_CFO_TAKEOVER'}[Node1: cf_takeover: cf.fm.takeoverStarted:notice]: Failover monitor: takeover started- 物理重新拔插后主板未启动