MetroCluster IP 中的 SwitchUnreachable_alert
适用于
- ONTAP 9
- FAS/AFF
- MetroCluster IP
问题
SwitchUnreachable_Alert在 MCC IP 集群交换机上引发
[node1: cshmd: hm.alert.raised:alert]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = Switch_A1(XXXXXXX) raised by monitor ethernet-switch Issue 1 : cluster switch and cluster management IP not reachable.
- 集群互连交换机报告未受 CSHM 监控:
ClusterA::*> system cluster-switch show
Switch Type Address Model
--------------------------- ------------------ ---------------- ---------------
switch_A1(xxxxxxxxxxx) cluster-network 10.1.1.111 NX3132V
Serial Number: xxxxxxxxxxx
Is Monitored: false
Reason: xxxxxxxxxxxxxxx
Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 7.0(3)I4(1)
Version Source: CDP
- 设备发现中存在不受监控的交换机:
::> network device-discovery show
Node/ Local DiscoveredProtocol Port Device Interface Platform----------- ------ ------------------------- ---------------- ----------------node1/cdp e0a NX3132V-sw1.example.com(XXXXXXXXXXX) 0/1 NX3132V e0b NX3132V-sw2.example.com(XXXXXXXXXXX) 0/1 NX3132Vnode2/cdp e0a NX3132V-sw1.example.com(XXXXXXXXXXX) 0/2 NX3132V e0b NX3132V-sw2.example.com(XXXXXXXXXXX) 0/2 NX3132V
- 从运行 CSHM 后台程序的节点的 node-mgmt LIF 尝试 ping 集群交换机管理 IP 地址时,没有应答。
- 集群 LIF 能够成功 ping 通交换机。
- 集群交换机管理 IP 配置正确。
- 集群 ping-cluster 在所有路径上都成功。
- 没有观察到集群交换机和管理交换机之间的物理连接问题。