触发SinglePathToDiskShely_Alert和"disk冗余失败"Auto支持
适用场景
- ONTAP 9
- SAS HBA
问题描述
- EMS报告""
DISK REDUNDANCY FAILED
Mon Oct 17 19:16:56 +0800 [Nodename: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
Mon Oct 17 19:16:56 +0800 [Nodename: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
- EMS报告""
SinglePathToDiskShelf_Alert
星期二10月11日23:31:23 +0800 [nokename:mgwd:callHome.hm.alert.major:alert]:为运行状况监控进程呼叫住宅nchm:SinglePathToDiskShelf_Alert[159491309057xxxx]。
- system-Health警报.XML报告以下警报:
Controller Nodename has only a single-path configuration to disk shelf 18.10. This might occur when the controller does not have dual-path configuration to stack 18, a SAS HBA port on the controller connected to the disk shelf is disabled, or shelf-to-shelf cabling is incorrect.