SinglePathToDiskShelf_Alert
适用于
- FAS/AFF 系统
- ONTAP 9
问题描述
- 检测到以下警告
#02 alertTrap <DC=[Node-02] HOST=[**-**.ecl.ntt.com.local] IPADDRESS=[*****] TAG_Resource=[****] xSLAkey=[alertTrap] TAG_Ifdesc=[]>
[ productTrapData.0 = "callhome.hm.alert.major:Call home for Health Monitor process nchm: SinglePathToDiskShelf_Alert[****]." productSerialNum.0 = "1-80-****", [DC=Node-02]
- EMS 错误消息。(也可以自行恢复)
[nchmd: hm.alert.raised:alert]: Alert Id = SinglePathToDiskShelf_Alert , Alerting Resource = **** raised by monitor node-connect
[nchmd: hm.alert.cleared:notice]: Alert Id = SinglePathToDiskShelf_Alert , Alerting Resource = ****cleared by monitor node-connect
- 或者在将新磁盘架添加到系统后,出现磁盘架单路径警报。
Node-02
node-connect SinglePathToDiskShelf_Alert 4168583XXXX905936 SAS-connect
Major Cable_tamper
Controller Node-02 has only a single-path configuration to disk shelf 2.10.
This might occur when the controller does not have dual-path configuration to stack 2, a SAS HBA port on the controller connected to the disk shelf is disabled, or shelf-to-shelf cabling is incorrect.
- 此外,我们观察到该系统处于混合路径中。
NetApp Release 9.13.1P6: Tue Dec 5 11:06:25 EST 2023
System ID: 0538168XXX (Node-01); partner ID: 0538168XXX (Node-02)
System Serial Number: 652040000XXX (Node-01)
System Rev: B1
System Storage Configuration: Mixed-Path HA
NetApp Release 9.13.1P6: Tue Dec 5 11:06:25 EST 2023
System ID: 0538168XXX (Node-02); partner ID: 0538168XXX (Node-01)
System Serial Number: 652040000XXX (Node-02)
System Rev: B1
System Storage Configuration: Mixed-Path HA