由于"来自 Node_Name (SHELF_FAULT) ERROR 的 HA 组通知",磁盘架 ID 已更改
适用于
- ONTAP 9
- AFF 系统
- ASA 系统
- FAS 系统
- DS2246/DS224/DS212 磁盘架
问题
- 已触发 AutoSupport 警报:
HA Group Notification from Node_Name (SHELF_FAULT) ERROR
- 货架 ID 已更改,
SHELF ID DELTA显示在来自 AutoSupport 的STORAGE-FAULT中:
Enclosure Status: non-critical
Channel: 0a
Shelf: 87
Vendor Unique Element 83-IOM12E: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM12E A] : CRITICAL 02,09,00,A4 SHELF ID DELTA, MASTER, RESERVED, RESERVED, RESERVED
2 [IOM12E B] : NONCRITICAL 03,01,00,20 SHELF ID DELTA, RESERVED
EMS日志中出现错误:
Nov 21 13:41:54 JST [node_name: dsa_worker3: ses.status.ModuleError:alert]: DS224-12 (S/N Serial_No) shelf 92 on channel 0a SAS expander error for SAS shelf electronics 1: critical status; Shelf ID changed. This module is on the rear of the shelf at the top left, on shelf module A.
Nov 21 13:41:54 JST [node_name: dsa_worker3: ses.shelf.changedId:error]: Disk shelf module 2 on disk shelf 0a.92 indicates that the disk shelf ID has been changed since the disk shelf module was powered on. This module is on the rear of the shelf at the top right, on shelf module B.
Nov 21 13:42:00 JST [node_name: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
Nov 21 13:42:03 JST [node_name: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0a. Check fans, power supplies, disks, and temperature sensors.
Nov 21 13:42:03 JST [node_name: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT