共享和已分配SwitchtoShelter_Alert
适用场景
- AF/ FAS
- N9K-C9336C-FX2
问题描述
- 已从集群中的所有磁盘架报告以下运行状况警报:
Node: Node1 Alert ID: SharedandDedicatedSwitchtoShelf_Alert
Resource: Shelf UUID: XX76889639XXXXXXXXXX
Severity: Major Indication
Time: Thu Mar 21 15:13:05 2024
Suppress: false Acknowledge: false
Probable Cause: Shelf 6.20 is connected to both shared and dedicated storage switches.
Possible Effect: This configuration is not supported.
Corrective Actions:
1. Consult the guides that apply to your NVMe shelf and shared switch to review the cabling rules for your system.
2. Connect shelf 6.20 only through either shared or dedicated storage switches.
- 此外、还会同时发出以下运行状况警报:
Node Node1
Monitor node-connect
Alert ID SharedAndDedicatedSwitchToHA_Alert
Alerting Resource Node1
Subsystem SAS-connect
Indication Time Wed Mar 19 09:58:12 2025
Perceived Severity Major
Probable Cause Cable_tamper
Description Controller "Node1" is connected to both shared switch "switch01" and dedicated storage switch "switch02". This configuration is not supported.
Corrective Actions 1. Consult the guide "Setup and configuration guide for Cisco shared switches" to review the cabling rules for your system.
2. Connect controller Node1 to NVMe shelves only through either shared or dedicated storage switches.
Possible Effect Cluster network connectivity will be lost if shared switch switch01 fails.
Acknowledge false
Suppress false
Policy SharedAndDedicatedSwitchToHA_Policy
Acknowledger
Suppressor
Additional Information Switches: switch01, switch02
Shelves: 5.2, 5.3, 5.1
Initiator Ports: -
Port Connections: e5a::switch01:Ethernet1/12, e5b::switch02:Ethernet1/12
Alerting Resource Name Node Node1
Additional Alert Tags quality_of_service
- 确认是否已按照NetApp建议为磁盘架端口布线。
- 验证交换机和集群交换机的RC框架 文件和端口连接。