跳转到主内容

SP/BMC 升级成功后,SPAutoUpgradeFailedMajorAlert 仍保留在 SYSTEM-HEALTH-ALERT-PERSISTENT 中

Views:
7
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9
  • 服务处理器 (SP)
  • 主板管理控制器 (BMC)
  • 固件升级

问题

  • 在 ONTAP 升级期间 SP 自动固件升级失败后,会生成运行状况警报 SPAutoUpgradeFailedMajorAlert

Cluster::> system health alert show -instance

                      Node: Node01
                   Monitor: controller
                  Alert ID: SPAutoUpgradeFailedMajorAlert
         Alerting Resource: SP Upgrade
                 Subsystem: Service-Processor
           Indication Time: Tue Jun 28 21:04:44 2022
        Perceived Severity: Major
            Probable Cause: Configuration_error
               Description: A Service Processor automatic firmware update failure was detected, which can result in Service Processor not being updated to the latest available compatible firmware package.
        Corrective Actions: 1. Use the "system service-processor image show" command to display the firmware version that SP is currently booted from.
2. Manually upgrade Service Processor by using the "system service-processor image update" command.
3. Allow sufficient time for the system to update Service Processor firmware to the specified SP firmware package.
4. Contact the technical support if the alert persists.
           Possible Effect: Suboptimal system behavior can result from Service Processor not being updated to the latest available compatible firmware package.
               Acknowledge: false
                  Suppress: false
                    Policy: SPAutoUpgradeFailedMajorAlertPolicy
              Acknowledger: -
                Suppressor: -
    Additional Information: New firmware available: false
                            New firmware Version : Not Applicable
                            Auto update: true
                            Auto update  Status: installed
                            Previous AutoUpdate Status : failed
    Alerting Resource Name: SP Upgrade
     Additional Alert Tags: device

  •  即使在删除 SPAutoUpgradeFailedMajorAlert 后,SP 固件随后升级成功且所有健康子系统均报告正常,该警报仍会继续出现在  SYSTEM-HEALTH-ALERT-PERSISTENT.XML 下的 AutoSupport 中。

        Cluster::> system health alert delete -node * -alert-id SPAutoUpgradeFailedMajorAlert

        Error: There are no entries matching your query.

        Cluster::> system health subsystem show

        Subsystem Health

        ----------------- ------------------

        SAS-connect ok

        Environment ok

        Memory ok

        Service-Processor ok

        Switch-Health ok

        CIFS-NDO ok

        Motherboard ok

        IO ok

        MetroCluster ok

        MetroCluster_Node ok

        FHM-Switch ok

        FHM-Bridge ok

        SAS-connect_Cluster ok

        13 entries were displayed.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.
  • 这篇文章对您有帮助吗?