跳转到主内容

ONTAP 升级中 BMC 更新失败期间的 SPAutoUpgradeFailedMajorAlert

Views:
3
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

适用于

  • FAS2720
  • FAS2750
  • 分阶段的 ONTAP 升级

问题描述

  • 在从 9.7P22 到 9.9.1P19 然后到 9.13.1P9 的分阶段 ONTAP 升级期间,BMC 更新在 HA 一个节点上失败,保持在旧版本 11.9P1。

观察到以下EMS log情况 SPAutoUpgradeFailedMajorAlert

 [?]  Wed Jul 09 15:37:10 +0900 [node02: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update has been successfully scheduled from  11.9P1 to 11.10'}
 [?]  Wed Jul 09 15:37:20 +0900 [node02: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update from 11.9P1 to 11.10 has been triggered.'}
 [?]  Wed Jul 09 15:37:51 +0900 [node02: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP firmware image has been successfully transferred to SP using network interface.'}
 [?]  Wed Jul 09 15:37:51 +0900 [node02: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params: {'reason': 'Unable to successfully update SP firmware using network interface'}
 [?]  Wed Jul 09 15:37:52 +0900 [node02: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.
 [?]  Wed Jul 09 15:39:10 +0900 [node02: nphmd: hm.alert.raised:alert]: Alert Id = SPAutoUpgradeFailedMajorAlert , Alerting Resource = SP Upgrade raised by monitor controller
 [?]  Wed Jul 09 15:57:34 +0900 [node02: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update has been successfully scheduled from  11.9P1 to 11.10'}
 [?]  Wed Jul 09 15:57:45 +0900 [node02: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP Firmware network update from 11.9P1 to 11.10 has been triggered.'}
 [?]  Wed Jul 09 15:58:15 +0900 [node02: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'SP firmware image has been successfully transferred to SP using network interface.'}
 [?]  Wed Jul 09 15:58:15 +0900 [node02: servprocd: sp.servprocd.upd.unexpt.evts:debug]: params: {'reason': 'Unable to successfully update SP firmware using network interface'}
 [?]  Wed Jul 09 15:58:15 +0900 [node02: servprocd: sp.servprocd.upd.error:error]: SP update error: SP firmware update failure has been detected.
​​​​​​

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.