由于FAS2820出现温度过低故障、温度传感器xx出现温度错误

Views:
23
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • FAS2820
  • ONTAP 9.13.1.

问题描述

  • 两个节点报告CPU温度传感器11或14温度过低故障、然后间歇性自动恢复:

Fri Dec 15 09:02:20 +0900 [Node-01: dsa_worker0: ses.status.temperatureError:error]: DS212-12 (S/N SHJSG2338000430) shelf 0 on channel 0b temperature error for Temperature sensor 11: critical status; undertemperature failure. Current temperature: 0 C (32 F). This module is on the rear of the shelf at the top left, on shelf module A.
Fri Dec 15 09:02:29 +0900 [Node-01: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
Fri Dec 15 09:02:29 +0900 [Node-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
Fri Dec 15 09:04:08 +0900 [Node-01: dsa_worker2: ses.status.temperatureInfo:info]: DS212-12 (S/N SHJSGxxxxxxxxxx) shelf 0 on channel 0b temperature information for Temperature sensor 11: normal status.

Tue Dec 19 09:03:22 +0900 [Node-02: dsa_worker2: ses.status.temperatureError:error]: DS212-12 (S/N SHJSGxxxxxxxxxx) shelf 0 on channel 0b temperature error for Temperature sensor 14: critical status; undertemperature failure. Current temperature: 0 C (32 F). This module is on the rear of the shelf at the top right, on shelf module B.
Tue Dec 19 09:03:31 +0900 [Node-02: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
Tue Dec 19 09:03:31 +0900 [Node-02: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
Tue Dec 19 09:03:58 +0900 [Node-02: dsa_worker1: ses.status.temperatureInfo:info]: DS212-12 (S/N SHJSGxxxxxxxxxx) shelf 0 on channel 0c temperature information for Temperature sensor 14: normal status.

  • SHELF-FAULT 显示:

Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
 ...
 11: CRITICAL          02,00,14,03   UT WARNING, UT FAILURE  
 ...

Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
 ...
 14: CRITICAL          02,00,14,03   UT WARNING, UT FAILURE
 ...

  • SP和磁盘架固件为最新版本:

 Service Processor           Status: Online
  Firmware Version:   17.2P1
  Mgmt MAC Address:   d0:39:ea:ae:4f:32
  Ethernet Link:      up, 1Gbps
  Using DHCP:         no

 Shelf 0: DS212-12  Firmware rev. IOM12G A: 0111  IOM12G B: 0111

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.