适用于

  • ONTAP 9
  • FAS9500
  • 存储配置为 Quad-path

问题描述

  • SYSCONFIG -A 报告 SAS 端口关闭:

slot 2: SAS Host Adapter 2c (PMC-Sierra PM8072 rev. C, SAS, <OFFLINE (hard)>)

  • EMS 报告 DISK REDUNDANCY FAILED 错误:

[node01: pmcsas_admin_0: sas.port.down:debug]: SAS port "2c" went down.
[node01: pmcsas_admin_0: sas.cable.pulled:debug]: Cable attached to SAS port "2c" was pulled out.
[node01: svc_queue_thread: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage
[node01: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • 环境报告外部货架仍然能够读取 SAS 电缆信息:

Channel: 11b
Shelf: 50

SAS cable information by element:
[1] Vendor: Amphenol
Type: MINI-SAS HD passive copper 5m ID: 00 Swaps: 0
Serial number: xxxxxxxxxx Part number: 112-00439+A0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 