SAS连接子系统由于缆线不受支持而处于降级状态
适用场景
ONTAP 9
问题描述
- SAS连接子系统处于已降级状态。示例:
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect degraded
Environment ok
...
- 多个EMS警报。示例:
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678910 raised by monitor node-connect
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678911 raised by monitor node-connect
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678912 raised by monitor node-connect
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678913 raised by monitor node-connect
[node_name: nchmd: hm.alert.raised:alert]: Alert Id = DegradedShelfToShelfCabling_Alert , Alerting Resource = 012345678914 raised by monitor node-connect
[node_name: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: DegradedShelfToShelfCabling_Alert[012345678914].
System health alert
示例:
Monitor node-connect
Alert ID DegradedShelfToShelfCabling_Alert
Alerting Resource 012345678910
Subsystem SAS-connect
Indication Time Wed Apr 27 05:37:56 2022
Perceived Severity Major
Probable Cause Cable_tamper
Description
Disk shelf 0a.shelf10 is connected only through 2 paths on IOM A and 2 paths on IOM B either to adjacent disk shelves or to the partner controller of the GobettiInfraTS-02 controller.
Because controller node_name is connected to stack 0 through a quad-path configuration, disk shelf 0a.shelf10 must be connected with double-wide cabling to adjacent disk shelves or quad-path to the partner controller.
Corrective Actions
1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. If disk shelf 0a.shelf10 is connected to another disk shelf, verify that disk shelf 0a.shelf10 is connected with double-wide cabling.
3. If disk shelf 0a.shelf10 is connected to the partner controller, verify that stack 0 containing disk shelf 0a.shelf10 is connected through a quad-path configuration.
4. Contact technical support if the alert persists.
Possible Effect Inconsistent cabling might cause degraded performance.
Acknowledge false
Suppress false
Policy DegradedShelfToShelfCabling_Policy
- SAS缆线不兼容。示例:
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8072 rev. C, SAS, <UP>)
Mini-SAS HD Vendor: FCI Electronics
Mini-SAS HD Part Number: 10129376-3020LF+A
Mini-SAS HD Type: Passive Copper (unequalized) 4m ID:00
Mini-SAS HD Serial Number: 1778214CR0028A00