由于主板故障导致反复出现 PSU 传感器"不可读"事件
适用于
- AFF-A400
- ONTAP 9.13.1
问题
- 尽管之前已更换 PSU 并升级了 Service Processor 固件,但仍观察到重复的 PSU 故障事件。
- EMS 日志显示 PSU1 的传感器值不可读,随后显示恢复消息:
示例:
[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VIN is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VOUT is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 CurrIIN is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 IOUT is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 PIN is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 POUT is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FAN is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.ok:info]: Chassis power supply 1 is OK.