跳转到主内容

在单个集群端口上接收 NodeIfInErrorsWarnAlert 警告

Views:
1,039
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

适用于

  • AFF-A800/FAS8300/FAS8700/AFFA400
  • BES 53238 集群网络交换机
  •  Cisco 集群交换机

问题

  • 正在为集群中的单个集群端口引发健康警报

Node: node1
Monitor: controller
Alert ID: NodeIfInErrorsWarnAlert
Alerting Resource: node1/e0a
Subsystem: Motherboard
Indication Time: Thu Jun 05 16:28:52 2025
Description: The percentage of inbound packet errors of node "node1" on interface "e0a" is above the warning threshold.

  • EMS 正在被 hm 警报淹没,这些警报在几分钟内被触发和清除
 
Wed Jun 04 17:53:52 +0530 [node1: nphmd: hm.alert.raised:alert]: Alert Id = NodeIfInErrorsWarnAlert , Alerting Resource = node1/e0a raised by monitor controller
Wed Jun 04 17:58:52 +0530 [node1: nphmd: hm.alert.cleared:notice]: Alert Id = NodeIfInErrorsWarnAlert , Alerting Resource = node1/e0a cleared by monitor controller
Wed Jun 04 19:43:52 +0530 [node1: nphmd: hm.alert.raised:alert]: Alert Id = NodeIfInErrorsWarnAlert , Alerting Resource = node1/e0a raised by monitor controller
Wed Jun 04 19:48:52 +0530 [node1: nphmd: hm.alert.cleared:notice]: Alert Id = NodeIfInErrorsWarnAlert , Alerting Resource = node1/e0a cleared by monitor controller
 
  • 在故障端口上看到 CRC 错误

-- interface e0a (272 days, 3 hours, 50 minutes, 43 seconds) --
RECEIVE
Total frames: 215g | Frames/second: 9164 | Total bytes: 461t
Bytes/second: 19624k | Total errors: 1458k | Errors/minute: 4
Total discards: 26 | Discards/minute: 0 | Multi/broadcast: 18793k
Non-primary u/c: 0 | CRC errors: 1456k | Long frames: 0
Jabber: 2417 | Length errors: 0 | No buffer: 0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.