更新前检查获取错误:磁盘架和传感器检查
适用场景
- ONTAP 9.4P7、9.4P8、9.7P3、9.7P6、9.7P11、 9.10.1P3、9.12.1、9.13.1.
- ANDU升级验证
- 更新前检查
- 磁盘架和传感器检查
问题描述
- 更新前检查获取错误:磁盘架和传感器检查
错误:验证检查无法正确执行。
操作:如果重试后问题仍然存在、请删除软件包并重新下载。
- system node Environment传感器show命令返回错误。
Eaxmple:
::> system node environment sensors show
Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
Node-01
PSU2 FRU normal
GOOD
PSU1 FRU normal
GOOD
SP Status normal
IPMI_HB_OK
mSATA Status normal
OK
mSATA Pres normal
PRESENT
Error: show failed: The Service Processor on node "Node-01" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.
The Service Processor on node "Node-01" is not reachable. Verify that the SP or BMC is online, verify that api-service is enabled on the SP or BMC, verify that the partner node is running, check if pings from SP or BMC to partner node work, check if hw-assist keep-alives are normal, check that network ports are configured correctly and are functional (up). Then, try the command again.