跳转到主内容

节点死机,无法启动,出现错误 panic: rootfs.uzip

Views:
106
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

ONTAP 9

起诉

  • 引导设备出现问题的节点将死机或无法从 Loader 引导,我们会看到以下消息之一:
  • 以下内容可见于 EMS-LOG.GZ

PANIC: g_vfs_done(): rootfs.uzip read error - suspect boot device in process g_up on release 9.7P4 (C)
PANIC: Process mgwd unresponsive for 158 seconds (mgwd startup: "(2139)") in process nodewatchdog
PANIC: Process vifmgr unresponsive for 658 seconds in process nodewatchdog on release 9.7P18
panic: g_vfs_done():md0.uzip[READ(offset=XXXXXXXXXX, length=XXXX)]errovm_fault: pager read error, pid XXXX (notifyd) fs=ufs [attempt 10]
PANIC : vm_fault: page read error for pid X (notifyd) fs=ufs, trys=10.

  • 控制台日志 - 启动失败:

md0.uzip: UZIP(zlib) inflate() failed
Could not load fat://boot0/X86_64/freebsd/image1/kernel:Device not found
ERROR: Error booting OS on: 'boot0' file: fat://boot0/X86_64/freebsd/image1/kernel (boot0,fat)
*** command status = Device not found(-6)

  • BMC 事件日志显示以下错误:

[Controller.notice]: Appliance user command panic.
[IPMI.notice]: 001f | 02 | EVT: 6f406fff | Sensor 255 | Assertion Event, "Storage OS stop/shutdown" [BMC.critical]: Filer Reboots
[IPMI.notice]: (PUA) Enable power to all PCIe slots
[IPMI.notice]: (PUA) Enable power to all PCIe on board device
[IPMI.notice]: (PUA) P_stat :slots=0x0,onboard_devs=0x0,final
[IPMI.notice]: (PUA) Power status of all PCIe slots unchanged
[IPMI.notice]: 0023 | 02 | EVT: 6fc203ff | System_FW_Status | Assertion Event, "Memory Initialization done"
[SysFW.warning]: Error loading ENV variables, creating defaults*
[SysFW.warning]: Failed to read FW image on boot media: Device not found. Auto up
[SysFW.warning]: date skipped
[IPMI.notice]: 0024 | 02 | EVT: 6fc220ff | System_FW_Status | Assertion Event, "Bootloader is running"

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.