适用于

  • FAS8300、FAS8700
  • AFF A400

问题

  • 在正常系统运行期间看到以下意外系统中断消息:

PANIC : User initiated "system core" nmi on cpu
version: 9.7P11:03:00 EST 2021
conf : x86_64.optimize
cpuid = 5
Uptime: 333d11h2m17s
ahcich2: AHCI reset done: devices=00000001
fpudna: fpcurthread == curthread

PANIC: User initiated "system core" nmi on cpu 5 in process idle: cpu5 on relea on Thu Feb 10 02
version: 9.7P
compile flags: x86_64.optimize
HA: current time (in sk_msecs) 28810833068 (in sk_cycles) 63235544303788032
DUMPCORE: START
Dumping to boot device.

  • 在 BMC 事件日志中可以看到以下内容:

 576 | 02/10/2022 | 14:28:12 | Critical Interrupt #0xb0 | NMI/Diag Interrupt | Asserted
577 | 02/10/2022 | 14:28:14 | Watchdog 2 #0xb1 | Timer interrupt (NMI/SMS/OS) | Asserted
578 | 02/10/2022 | 14:38:29 | OS Stop/Shutdown #0xff | OS graceful shutdown | Asserted

  • 在 (BMC) SP-LATEST-SYSLOG 中可以看到以下内容:

[18425808.070000] BUG: Bad page state in process ipmitool pfn:96a04

  • panic 消息指示用户通过执行系统核心启动了 panic,但管理员确实启动了 NMI。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.