跳转到主内容

PSU在两个节点上读取FRU EEPROM时显示错误

Views:
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用于

  • AFF-A30

问题描述

  • 警报,表明其中一个电源单元出现故障(PSUx -> 可以是 PSU1 或 PSU2)。
  • 系统日志和 AutoSupport 报告显示"电源不存在"、"电源状态严重"、"检测到 PSU 不匹配"和"读取 FRU EEPROM 时出错"等消息。

AutoSupport 日志 (EMS-LOG):

[1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply x is degraded: PSUx In Pwr is Unreadable_x000D_
[1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply x is degraded: PSUx Out Pwr is Unreadable_x000D_
[1: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply x is degraded: PSU Mismatch is detected_x000D_
[xxxx01:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply x is degraded: PSUxInVolt is Unreadable_x000D_
[xxxx01:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply x is degraded: PSUxInCurr is Unreadable_x000D_
[xxxx01:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply x is degraded: PSUMismatch is detected_x000D__

命令输出(system controller environment show):

Node FRU Name State_x000D_
-----------------------------------------_x000D_
xxxxx101-01 PSU1 FRU ERROR_x000D_
xxxxx101-01 PSU2 FRU GOOD_x000D_
xxxxx101-02 PSU1 FRU ERROR_x000D_
xxxxx101-02 PSU2 FRU GOOD

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.