SAS 端口上的 PHY 状态已降级
适用于
- ONTAP 9
- SAS 机架
问题
- 控制器端 SAS 端口上的 PHY 降级,显示速度低于预期
slot 0: SAS Host Adapter 0b (Broadcom SAS3616W rev. 2, SAS, <UP>)
Firmware rev: 12.00.00.00
NVDATA rev: 12.03.01.03
Base WWN: 5:XXXXXX:XXXXXXX:e6
Temperature: Not Available
Phy State: [0] Enabled, 12.0 Gb/s
[1] Enabled, 12.0 Gb/s
[2] Enabled, 12.0 Gb/s
[3] Enabled, 6.0 Gb/s
Mini-SAS HD Vendor: MOLEX
Mini-SAS HD Part Number: 112-00453+A0
Mini-SAS HD Type: Optical (850nm VCSEL) 15m end_1
Mini-SAS HD Serial Number: 93XXXXXXXXXX29-A
slot 4: SAS Host Adapter 4c (PMC-Sierra PM8072 rev. C, SAS, <UP>)
MFG Part Number: Microsemi Corp. 110-03801 rev. A0
Part number: 111-03801+A0
Serial number: 0BXXXXXXXF4
Date Code: 20200921
Firmware rev: 03.08.09.00
Base WWN: 5:XXXXXX:XXXXXXX:08
Temperature: 44 C
Phy State: [0] Enabled, 12.0 Gb/s
[1] Enabled, 12.0 Gb/s
[2] Enabled, 12.0 Gb/s
[3] Enabled, 6.0 Gb/s
Mini-SAS HD Vendor: Amphenol
Mini-SAS HD Part Number: 112-00453+A0
Mini-SAS HD Type: Optical (850nm VCSEL) 15m ID:00
Mini-SAS HD Serial Number: APXXXXXXXXXX38
- SAS-EXPANDER-PHY-STATE 输出显示磁盘架 37 上的 PHY 11 已降级至 6.0 Gb/s。
Expander phy state on 0b.37 (NETAPP :DS21212IOM12 SHXXXXXXXXXXXXX95):
Pwr Invald Disprt Loss Phy CRC Phy
Pwr Ccl Rsv Rls DWord Error Sync Reset Error Change SATA
PHY/BAY STATE ON Cnt Cnt Cnt Count Count Count Prob Cnt Cnt Affiliation
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
0/P0:0 12.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
1/P0:1 12.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
2/P0:2 12.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
3/P0:3 12.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
4/P1:0 Disabled
5/P1:1 Disabled
6/P1:2 Disabled
7/P1:3 Disabled
8/P2:0 12.0 Gb/s --- --- --- --- 0 0 0 0 0 13 ----------------
9/P2:1 12.0 Gb/s --- --- --- --- 0 0 0 0 0 13 ----------------
10/P2:2 12.0 Gb/s --- --- --- --- 0 0 0 0 0 13 ----------------