问题描述

  • 在计划内断电期间、在节点2无法启动后发生异常关闭。
  • 从BMC命令行界面访问时、 Loader 提示符的状态、即使 boot_ontap 从 Loader 系统发生崩溃且无法重新启动也是如此。

PANIC  : NVRAM contents are invalid...

version: 9.8P6: Tue Aug  3 12:23:18 EDT 2021

conf : x86_64.optimize

cpuid = 0

KDB: stack backtrace:

vpanic() at vpanic+0x70d/frame 0xfffff7005c84fbf0

panic() at panic+0x43/frame 0xfffff7005c84fc50

sk_panic() at sk_panic+0x63/frame 0xfffff7005c84fcb0

boot_nv_jettison() at boot_nv_jettison+0xbb/frame 0xfffff7005c84fce0

boot_from_disk() at boot_from_disk+0x1df1/frame 0xfffff7005c850250

boot_manager() at boot_manager+0x1b7/frame 0xfffff7005c850280

rc_main() at rc_main+0x7f/frame 0xfffff7005c8502e0

fork_exit() at fork_exit+0xc7/frame 0xfffff7005c850330

fork_trampoline_sk() at fork_trampoline_sk+0xe/frame 0xfffff7005c850330

--- trap 0, rip = 0, rsp = 0, rbp = 0 ---

Uptime: 2m50s

ahcich2: AHCI reset done: devices=00000001

 

PANIC: NVRAM contents are invalid...   in SK process rc on release 9.8P6 (C) on Sat Jan  7 01:05:13 GMT 2023

version: 9.8P6: Tue Aug  3 12:23:18 EDT 2021

compile flags: x86_64.optimize

  • 检查 bootarg.init.boot_recovery,结果请参阅数字“8”。

LOADER-B> printenv bootarg.init.boot_recovery

 

Variable Name        Value

-------------------- --------------------------------------------------

bootarg.init.boot_recovery 8

  • 即使使用以下命令删除了bad标志、系统仍无法启动。

LOADER-B> priv set advanced

LOADER-B*> unsetenv bootarg.init.boot_recovery

LOADER-B*> saveenv

LOADER-B*> boot_ontap

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.