导联架温度过高故障警报
适用场景
- AFF / ASA / FAS
- DS2246
- ONTAP 9
问题描述
EMS log
显示SHELF_FAULT
错误:
[FAS-01: dsa_worker0: ses.status.temperatureWarning:alert]: DS2246 (S/N XXXXXXXXXXX) shelf 5 on channel 0b temperature warning for Temperature sensor 6: non-critical status; overtemperature warning. Current temperature: 66 C (150 F). This module is on the rear of the shelf on the lower right power supply.
[FAS-01: statd: monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
[FAS-01: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
STORAGE-FAULT
ASUP日志:
Enclosure Status: non-critical
Channel: 0b
Shelf: 5
Shelf Type: DS2246
...
Temperature Sensors:
Element Status Status Bytes Status Descriptions
1: OK 01,00,36,00
2: OK 01,00,3A,00
3: OK 01,00,3D,00
4: OK 01,00,53,00
5: OK 01,00,3C,00
6: NONCRITICAL 03,00,56,04 OT WARNING
7: OK 01,00,3E,00
8: OK 01,00,3F,00
ENVIRONMENT
ASUP日志:
安装的温度传感器元件列表:1、2、3、4、5、 6、7、8;有错误:6
主机架温度:
[1] 34 C (93 F)(环境) 正常温度范围
[2] 38 C (100 F)正常温度范围
[3] 41 C (105 F) 正常温度范围
[4] 63 C (145 F) 正常温度范围-------- > PSU1中的传感器
[5] 40 C (104 F) 正常温度范围
[6] 66 C (150 F)过热警告!----------------------- > PSU2中的传感器
[7]41 C (105 F) 正常温度范围
[8]42 C (107 F) 正常温度范围