问题描述

  • AutoSupport警报
    HA Group Notification (CLUSTER NETWORK DEGRADED) ALERT
  • EMS log 显示其中一个集群端口处于degraded 状态。

[vifmgr.reach.skipped:notice]: Network port e0d on node Node-01 was not scanned for reachability because it was administratively or operationally down at the time of the scan.
[vifmgr.port.monitor.failed:error]: The "link_flapping" health check for port e0d (node node-01) has failed. The port is operating in a degraded state.
[vifmgr.portDeg.lifMoved:notice]: LIF node-01_clus2 (on virtual server ****), IP address *****, is being moved to node node-01, port e0c from node node-01, 
port e0d because the port's health status is in a degraded state.

  • network port show 命令输出指示只有一个节点的端口处于degraded 状态。
    配对节点的两个集群端口均处于healthy  状态。

::> network port show
Node: Node-01
                          Speed(Mbps) Health
Port   IPspace    Broadcast Domain Link MTU  Admin/Oper  Status
--------- ------------ ---------------- ---- ---- ----------- --------
e0M     Default    Default      up   1500  auto/1000  healthy
e0a     Default    -         up   1500 auto/1000  healthy
e0b     Default    -         down 1500  auto/-    -
e0c     Cluster    Cluster      up   9000  auto/25000 healthy
e0d     Cluster    Cluster      up   9000  auto/25000 degraded
e2a     Default    -    down 1500  auto/-    -

Node: Node-02
                Speed(Mbps) Health
Port    IPspace    Broadcast Domain Link MTU  Admin/Oper  Status
--------- ------------ ---------------- ---- ---- ----------- --------
e0M     Default    Default      up   1500  auto/1000 healthy
e0a     Default    -         up   1500  auto/1000  healthy
e0b     Default    -         down 1500 auto/-    -
e0c     Cluster    Cluster      up   9000  auto/25000 healthy
e0d     Cluster    Cluster      up  9000  auto/25000 healthy
e2a     Default    -         down 1500  auto/-    -
e2b     Default    - down 1500  auto/-    -
14 entries were displayed.

  • 重置直接连接电缆不会改善这种情况。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.