由于缺少CDP信息、一个或多个节点未同时连接到两个集群交换机
适用场景
- ONTAP 9
- Cisco Nexus 3232
- 集群网络交换机
问题描述
- 尽管集群端口已启动且正常运行、但仍会显示以下警报:
cluster::*> system health alert show
Node: cluster-n03
Alert ID:ClusterSwitchConnectivity_Alert
Resource: cluster-n13
Severity: Major
Indication Time: Sun Jun 1820:27:06 2023
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, "cluster-n13" might lose access to the cluster. Corrective Actions: Verify that the switch "cluster-switch2(FOC1234567)" isconnected to the node "cluster-n13".
- 但是、此端口已启动且正常工作、但节点节点端口e1a上缺少远程设备(集群交换机)的CDP信息
- 只有
network device-discovery
在show命令输出中、才会在受影响的端口上看到交换机