跳转到主内容

检测到 " 两个互连链路之一出现故障 " 陷阱警报

Views:
26
Visibility:
Public
Votes:
2
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • FAS8080
  • ONTAP 9

问题描述

  • EMS log 通过互连端口 ib0a ,节点 1 节点和节点 2 之间的端口将立即断开链路并还原。 

[?] Sun May 23 13:06:00 JST [node 1: mlx4_intr_handler: ic.linkStatusChange:info]: HA interconnect: Port ib0a link is down.
[?] Sun May 23 13:06:00 JST [node 1: ctrl_hb_port_ib0a: ctrl.rdma.heartBeat:info]: HA interconnect: Missed heartbeat to XXX.XXX.XXX.XXX.
[?] Sun May 23 13:06:01 JST [node 1: monitor: monitor.globalStatus.nonCritical:error]: One of the two interconnect links has failed.
[?] Sun May 23 13:06:06 JST [node 1: mlx4_intr_handler: ic.linkStatusChange:info]: HA interconnect: Port ib0a link is up.

 

  • sysconfig -a 显示链路状态为活动。 

NetApp Release 9.1P16: Wed Nov 14 00:22:10 EST 2018
 System ID: 0537090755 (node 1); partner ID: 0537090720 (node 2)
 System Serial Number: 451713000103 (node 1)
 System Rev: C3

 Interconnect Port 1:
  Port Name:   ib0a
  Default GID:     XXXX:0000:0000:0000:00a0:9800:0035:XXXX
  Base LID:       0x3c
  Active MTU:      4096
  Data Rate:      40 Gb/s (4X) QDR
  Link State:     ACTIVE
  QSFP Vendor:     Molex Inc.
  QSFP Part Number:   112-00374 A0
  QSFP Type:      Active Optical 5m ID:00
  QSFP Serial Number: XXXXXXXXXXXXXX
 Interconnect Port 2:
  Port Name:   ib0b
  Default GID:     XXXX:0000:0000:0000:00a0:9800:0035:XXXX
  Base LID:       0x3d
  Active MTU:      4096
  Data Rate:      40 Gb/s (4X) QDR
  Link State:     ACTIVE
  QSFP Vendor:     Molex Inc.
  QSFP Part Number:   112-00374 A0
  QSFP Type:      Active Optical 5m ID:00
  QSFP Serial Number: XXXXXXXXXXXXXX

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 