适用场景

  • FAS2650
  • DS212C磁盘架
  • ONTAP 升级

问题描述

  • 控制器在升级期间未响应
  • 启动过程挂起并显示消息 Entering FM state:5 because mbFound:0 local inheadswap:0
  • 由于未找到根卷、控制器最终会重新启动

WARNING: there do not appear to be any disks attached to the system.
No root volume found.
Rebooting... (press ctrl-c during boot to break reboot loop)
Uptime: 6m10s
System rebooting...

 

  • 在维护模式下无法看到任何磁盘

*> disk show -v
Local System ID: 123456789

disk show: No disks attached to system.

  • 维护模式下SAS适配器缺少磁盘架和磁盘信息

     slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <UP>)
         Firmware rev:     03.08.09.00
         Base WWN:       5:00a098:00aec1a:30
         Temperature:     Not Available
         Phy State:      [0] Enabled, 12.0 Gb/s
                   [1] Enabled, 12.0 Gb/s
                   [2] Enabled, 12.0 Gb/s
                   [3] Enabled, 12.0 Gb/s
         Mini-SAS HD Vendor:     Amphenol     
         Mini-SAS HD Part Number:   X66032A+A0    
         Mini-SAS HD Type:      Passive Copper (unequalized) 2m ID:01
         Mini-SAS HD Serial Number: APF16340162481
     slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
         Firmware rev:     03.08.09.00
         Base WWN:       5:00a098:00aec1a:34
         Temperature:     Not Available
         Phy State:      [4] Enabled, 12.0 Gb/s
                   [5] Enabled, 12.0 Gb/s
                   [6] Enabled, 12.0 Gb/s
                   [7] Enabled, 12.0 Gb/s

  • sasadmin expander_map 显示了适配器0b的正确布线、但适配器0a的信息已损坏(例如、缺少磁盘架序列号)​​​​​​​​​​​​​​​​​​​​​​​​​​​​   

Expanders on channel 0a: 
Level   0: WWN 500a098007cb4815, ID  0, Serial Number '         ', Product '', Rev '', Slot A
Level   1: WWN 500a098007cb47b5, ID  0, Serial Number '         ', Product '', Rev '', Slot A

Expanders on channel 0b: 
Level   1: WWN 500a09800aec1a3f, ID  0, Serial Number ' SHFHU1736000204', Product 'DS22412IOM12E   ', Rev '0230', Slot A
Level   2: WWN 500a098007cb4811, ID  2, Serial Number ' SHFHU1739000214', Product 'DS22412IOM12A   ', Rev '0281', Slot A
Level   3: WWN 500a098007cb47a5, ID  1, Serial Number ' SHFHU1739000215', Product 'DS22412IOM12A   ', Rev '0281', Slot A
备份磁盘备份

  • 从适配器0a中拔下SAS缆线后、系统可以再次看到磁盘并启动
  • 重新拔插/更换IOM模块和SAS缆线无法解决问题描述 问题

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.