ONTAP 系统运行状况和环境报告 PSU 已降级,不可用和出现故障
适用场景
- FAS8200
- FAS8300
- FAS8700
- FAS8020
问题描述
- ONTAP 命令行界面报告:
::> system health subsystem show
Environment degraded
::> system node environment sensors show
Node Sensor State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
PSU1 VIN not-available - mV 90480 93600 261040 263120
PSU1 VOUT not-available - mV 11336 11440 12948 13156
PSU1 Curr IIN not-available - mA 0 - 9984 12012
PSU1 IOUT not-available - mA 0 - 130000 132000
PSU1 PIN not-available - W 7 14 1611 1796
PSU1 POUT not-available - W 7 14 1611 1796
PSU1 Inlet failed - C 0 - 58 63
PSU1 Hot failed - C 0 - 100 105
PSU1 FB Hot failed - C 0 - 100 105
PSU1 FAN not-available - RPM 800 1200 - -
- EMS 日志会持续报告以下事件:
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VIN is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VOUT is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Curr IIN is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 IOUT is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 PIN is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 POUT is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Inlet is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Hot is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FB Hot is Unreadable
Thu Sep 10 18:31:27 +0200 [Node-01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FAN is Unreadable
Thu Sep 10 18:35:56 +0200 [Node-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (PSU1 Inlet) is not readable.
Thu Sep 10 18:35:56 +0200 [Node-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (PSU1 Hot) is not readable.
Thu Sep 10 18:35:56 +0200 [Node-01: env_mgr: monitor.temp.unreadable:error]: The controller temperature (PSU1 FB Hot) is not readable.