跳转到主内容

自动启动后, ONTAP 将停止在 "arc4random: no padenropy cache" 处

Views:
84
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2008678739</a>
Specialty:
hw
Last Updated:

适用场景

  • FAS 型号
  • AFF型号

问题描述

  • 尝试启动时、控制器不会继续运行 arc4random: no preloaded entropy cache 、节点会无限期地停留、而不会再显示其他输出:
Starting AUTOBOOT press Ctrl-C to abort...
Loading X86_64/freebsd/image1/kernel:0x200000/1091637 0x30b000/10928224
0xf77060/3782856 0x1312928/13717912 0x200200/1016 Entry at 0xffffffff8030b000
Loading X86_64/freebsd/image1/platform.ko:0x2028000/4400432 0x245a530/596168
Starting program at 0xffffffff8030b000
Data ONTAP 9.7P5
arc4random: no preloaded entropy cache
  • SP日志BMC日志 是从节点收集的。
  • BMC事件日志可能指示多个传感器电量不足、并且 每次尝试启动时都会出现power_Good deasserted和CPU灾难性错误:

[IPMI.notice]: 002a | 02 | EVT: 0150008f | PVCCIN_CPU | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 1.502
[IPMI.notice]: 002b | 02 | EVT: 01520077 | PVCCIN_CPU | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1.249
[IPMI.notice]: 002c | 02 | EVT: 015003a8 | P5V | Assertion Event, "Lower Non-critical going low " | Reading: 0.078 | Threshold: 4.368
[IPMI.notice]: 002d | 02 | EVT: 015203a4 | P5V | Assertion Event, "Lower Critical going low " | Reading: 0.078 | Threshold: 4.264
[IPMI.notice]: 002e | 02 | EVT: 0150009b | PVDDQ_DDR4_AB | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 1.100
[IPMI.notice]: 002f | 02 | EVT: 01520099 | PVDDQ_DDR4_AB | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 1.086
[IPMI.notice]: 0030 | 02 | EVT: 0150004e | PVTT_DDR4_AB | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 0.554
[IPMI.notice]: 0031 | 02 | EVT: 0152004d | PVTT_DDR4_AB | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 0.547
[IPMI.notice]: 0032 | 02 | EVT: 015000ad | P3V3 | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 3.027
[IPMI.notice]: 0033 | 02 | EVT: 015200a9 | P3V3 | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 2.957
[IPMI.notice]: 0034 | 02 | EVT: 0300ffff | Power_Good | Assertion Event, "State Deasserted"
[IPMI.notice]: 0035 | 02 | EVT: 015008af | P12V | Assertion Event, "Lower Non-critical going low " | Reading: 0.496 | Threshold: 10.850
[IPMI.notice]: 0036 | 02 | EVT: 015208aa | P12V | Assertion Event, "Lower Critical going low " | Reading: 0.496 | Threshold: 10.540
[IPMI.notice]: 0037 | 02 | EVT: 01500000 | P12V_Curr | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 0.000
[IPMI.notice]: 0038 | 02 | EVT: 01520000 | P12V_Curr | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 0.000
[IPMI.notice]: 0039 | 02 | EVT: 0301ffff | CPU_Cat_Error | Assertion Event, "State Asserted"
[IPMI.notice]: 003a | 02 | EVT: 0301ffff | CPU_Therm_Trip | Assertion Event, "State Asserted"
[IPMI.notice]: 003b | 02 | EVT: 0301ffff | CNA0_Rst | Assertion Event, "State Asserted"
[IPMI.notice]: 003c | 02 | EVT: 0301ffff | CNA1_Rst | Assertion Event, "State Asserted"
[IPMI.notice]: 003d | 02 | EVT: 0301ffff | SAS_Rst | Assertion Event, "State Asserted"
[IPMI.notice]: 003e | 02 | EVT: 0301ffff | PCI_SW1_Rst | Assertion Event, "State Asserted"
[IPMI.notice]: 003f | 02 | EVT: 0301ffff | NVMe0_Rst | Assertion Event, "State Asserted"
[IPMI.notice]: 0040 | 02 | EVT: 0300ffff | CNA0_Rst | Assertion Event, "State Deasserted"
[IPMI.notice]: 0041 | 02 | EVT: 0300ffff | CNA1_Rst | Assertion Event, "State Deasserted"
[IPMI.notice]: 0042 | 02 | EVT: 0300ffff | SAS_Rst | Assertion Event, "State Deasserted"
[IPMI.notice]: 0043 | 02 | EVT: 0300ffff | PCI_SW1_Rst | Assertion Event, "State Deasserted"
[IPMI.notice]: 0044 | 02 | EVT: 0300ffff | NVMe0_Rst | Assertion Event, "State Deasserted" 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.