问题描述
monitor.shutdown.brokenDisk
自动关闭序列 到期时会显示消息 callhome.shutdown.pending
( RAID组在指定的时间间隔内处于降级模式。默认值通常为24小时)
- 节点关闭并显示以下错误、并且未执行接管:
示例:
[Node-01: statd: monitor.brokenDisk.notice:info]: When two disks are broken in raid_dp volume, the system shuts down automatically every 24 hours to encourage you to replace the disk. If you reboot the system it will run for another 24 hours before shutting down. (The 24 hour timeout may be increased by altering the "raid.timeout" value using the "options" command.)
[Node-01: statd: monitor.shutdown.brokenDisk:EMERGENCY]: data disk,parity disk in RAID group "/aggr0_n1/plex0/rg0" are broken. Halting system now.
[Node-01: shutdown_thread0: ha.localNodeShutDown:notice]: Shutdown of the local node has been initiated with inhibit_takeover set to TRUE.
[Node-01: shutdown_thread0: kern.shutdown:notice]: System shut down because : "BROKEN DISK".
- 同一个RAID-DP组中的两个磁盘出现故障、并处于"双降级"状态:
示例:
Aggregate aggr0_n1 (online, raid_dp, degraded) (block checksums)
Plex /aggr0_n1/plex0 (online, normal, active, pool0)
RAID group /aggr0_n1/plex0/rg0 (double degraded, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0d.03.0 0d 3 0 SA:A 0 SAS 10000 1142352/2339537408 1144641/2344225968
parity FAILED N/A 1142352/ -
data FAILED N/A 1142352/ -