由于环境原因关闭而关闭节点(电池不存在)
适用场景
- FAS 系统
- AFF系统
问题描述
- 节点因而关闭 Environmental Reason Shutdown (Battery not present)。
Mar 24 22:12:23 [nodeA:monitor.shutdown.emergency:EMERGENCY]:Emergency shutdown: Environmental Reason Shutdown (Battery not present)
 Terminated
 .
 Uptime: 8m47s
 System powering down...
- SP事件日志显示:
Record 431: Thu Apr 20 13:16:17 2023 [IPMI.emergency]: triggered OS halt: Battery not present
 Record 432: Thu Apr 20 13:16:22 2023 [IPMI.notice]: 7e01 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
 Record 433: Thu Apr 20 13:16:28 2023 [IPMI.notice]: 7f01 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"
 Record 434: Thu Apr 20 13:16:35 2023 [IPMI.notice]: 8001 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
 Record 435: Thu Apr 20 13:16:42 2023 [IPMI.notice]: 8101 | 02 | EVT: 0300ffff | Attn_Sensor1 | Assertion Event, "State Deasserted"
 Record 436: Thu Apr 20 13:16:48 2023 [IPMI.notice]: 8201 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
 Record 437: Thu Apr 20 13:18:35 2023 [IPMI.notice]: 8301 | 02 | EVT: 6f03ffff | Sensor 255 | Assertion Event, "Storage OS graceful shutdown"
 Record 438: Thu Apr 20 13:18:35 2023 [IPMI Event.critical]: System power down
 Record 439: Thu Apr 20 13:18:36 2023 [ONTAP.notice]: Appliance user command halt.
 Record 440: Thu Apr 20 13:18:35 2023 [IPMI.emergency]: Shutdown by Data ONTAP
- IPMI显示多个电池传感器不可用:
/usr/local/bin/ipmi sensors
 ===============================
 Sensor Name      | Current    | Unit       | Status     | LCR       | LNC       | UNC       | UCR
 -----------------+------------+------------+------------+-----------+-----------+-----------+-----------
 Bat_Temp         | -17.000    | degrees C  | cr         | 0.000     | 5.000     | 53.000    | 58.000
 Bat_Volt         | na         | Volts      | na         | 5.500     | 5.600     | 8.500     | 8.600
 Bat_Curr         | na         | Amps       | na         | na        | na        | 2.320     | 2.600
 Bat_Rem_Cap      | na         | Amps * hour | na         | na        | na        | na        | na
 Bat_Full_Cap     | na         | Amps * hour | na         | na        | na        | na        | na
 Bat_Charge_Curr  | na         | Amps       | na         | na        | na        | 2.200     | 2.300
 Bat_Charge_Volt  | na         | Volts      | na         | na        | na        | 8.900     | 9.000
 Bat_Design_Cap   | na         | Amps * hour | na         | na        | na        | na        | na
 Bat_Initial_Fcc  | na         | Amps * hour | na         | na        | na        | na        | na
 Bat_Dstg_Cycles  | na         | cycles     | na         | 2.000     | 5.000     | na        | na
 Bat_Power_Fault  | 0x0        | discrete   | Asserted   | na        | na        | na        | na
 Bat_Dsg_FET_Flt  | na         | discrete   | na         | na        | na        | na        | na
 Bat_Chg_FET_Flt  | na         | discrete   | na         | na        | na        | na        | na
 Bat_Pack_Invalid | 0x0        | discrete   | Asserted   | na        | na        | na        | na
 Bat_Cycle_Cnt    | na         | cycles     | na         | na        | na        | na        | na
 Bat_Lrn_Active   | na         | discrete   | na         | na        | na        | na        | na