跳转到主内容

节点报告PC电源不足严重状态

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • FAS2720
  • ONTAP 9

问题描述

  • 由于启动介质不可访问、节点B发生崩溃重新启动并过渡到Loader提示符。

PANIC: thread (swi4: clock (0)) on cpu 11 hung for 4001 milliseconds in process swi4: clock (0) on release 9.7P12 (C) on Fri Mar 7 11:05:17 JST 2025

  • 在 节点B上更换启动介质期间、 节点A 检测到磁盘架故障、节点B处于 PC INSUFFICIENT POWER 严重状态。

EMS日志:

<LR d="11Mar2025 12:31:16" n="node-01"・・・・

<ses_status_procCplxError_1

        prodChannel="DS212-12 (S/N SHXXXXXXXXXXX19) shelf 0 on channel 0b"

        typeText="Processor Complex"

        electrNumber="2"

        errorMsg="PCM on partner not installed"

        errorText=""

        locationText="This module is on the unknown location"/>

</LR>

<LR d="11Mar2025 12:40:34" n="node-01"・・・・

<monitor_shelf_fault_1

        channel="0b"/>

</LR>

<LR d="11Mar2025 12:40:34" n="node-01"・・・・

<callhome_shlf_fault_1

        subject="SHELF_FAULT"/>

存储故障

Enclosure Status: critical

Channel: 0b

Shelf: 0

Shelf Type: DS212-12

Product Serial Number: SHXXXXXXXXXXX19

Module Type: IOM12E

:

Vendor Unique Element 88-IOM12E: (PCM)

Element Status         Status Bytes  Status Descriptions

  1: OK                01,01,00,00  

  2: CRITICAL          02,01,00,01  PC INSUFFICIENT POWER

 

  • 传感器2在处理器组合件连接元件上出现错误。

环境:

Environment for channel 0a
   Number of shelves monitored: 1   enabled: yes
   Environmental failure on shelves on this channel? yes

   Channel: 0a
   Shelf: 0
   SES device path: local access: 0b.00.99
   Module type: IOM12E; monitoring is active  
   Shelf status: critical condition
   SES Configuration, shelf 0:

   Processor Complex attached element list: 1, 2 with error: 2
   SAS Expander Module installed element list: 1, 2; with error: none
   SAS Expander master module: 1

  • 两个节点均处于多路径SAS连接状态、 节点B上处于严重状态的IOM12E 似乎运行正常。
  • 更换 节点B 不会解决问题描述问题。

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.