问题描述

  • 合作伙伴主板重新安置期间的节点崩溃
  • 节点在合作伙伴重新安置期间开始失去对磁盘的访问权限,ems-log 报告
Node-01: kernel: nvme.link.error:error]: PCIe link initialization error for NVMe SSD in slot X
Node-01: kernel: nvme.link.error:error]: PCIe link initialization error for NVMe SSD in slot X
Node-01: kernel: nvme.link.error:error]: PCIe link initialization error for NVMe SSD in slot X
Node-01: kernel: nvme.link.error:error]: PCIe link initialization error for NVMe SSD in slot X
Node-01: kernel: nvme.link.error:error]: PCIe link initialization error for NVMe SSD in slot X
Node-01: kernel: nvme.link.error:error]: PCIe link initialization error for NVMe SSD in slot X
Node-01: scsi_cmdblk_strthr_admin: disk.timeout.flush.start:debug]: Aggressive timeout flush started on disk 0n.X
  • Panic String 报告
Node-01: splog_main: mgr.stack.string:notice]: Panic string: aggr Node-01_n2_root: raid volfsm, fatal multi-disk error..  Raid type - raid_dp Group name plex0/rg0 state NORMAL. 6 disks failed in the group. Disk 0
Node-01: splog_main: mgr.stack.at:notice]: Panic occurred at: Fri Feb  7 09:28:24  2025
Node-01: splog_main: mgr.stack.proc:notice]: Panic in process: config_thread
 
  • 在重新安装 Partner 期间,两个节点都出现问题
  • 需要重新安装出现故障的节点的主板以恢复消失的磁盘

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 