跳转到主内容

由于DS2246磁盘架温度过高、节点关闭

Views:
13
Visibility:
Public
Votes:
0
Category:
disk-shelves<a>2009537652</a>
Specialty:
hw
Last Updated:

适用场景

DS2246磁盘架

问题描述

  • 由于一个磁盘架温度过高、系统关闭。
  • 事件消息示例:
[node_name: env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Ambient temperature is warning high. System will be shutdown in 2 minutes
[node_name: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: LED2 Temp is warning high (43 C).
[node_name:env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: MP Temp3 is warning high (45 C).
[node_name: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high.. Disk shelf fault.
[node_name: env_mgr: callhome.chassis.overtemp:EMERGENCY]: Call home for CHASSIS OVER TEMPERATURE SHUTDOWN
[node_name: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE
  • 磁盘架风扇状态在 storage show fault 输出中为严重。示例

::>system node run -node <node_name> -command "storage show fault"
...
Fans:
Element Status         Status Bytes  Status Descriptions
1: OK                01,03,0C,A6
2: OK                01,03,1D,A6
3: OK                01,03,1B,A6
4: CRITICAL      02,01,B8,A1

  • 重新拔插PSU2后、此风扇所在的位置仍然存在问题描述

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.