跳转到主内容

网络端口报告已关闭

Views:
13
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

  • FAS 2650
  • FAS 8300
  • Cisco C9500-12Q

问题

  • 网络端口报告为关闭,如 EMS-LOG-FILE 所示

[Node-02: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0d: Link down, check cable.
[Node-02: vifmgr: vifmgr.port.ifgrpRemovePort:notice]: Port e0d, node Node-02 has been removed from ifgrp a0a.
[Node-02: mgmt_port_link_status_poll: netif.linkUp:info]: Ethernet e0d: Link up.
[Node-02: vifmgr: vifmgr.portup:notice]: A link up event was received on node Node-02, port e0d.
[Node-02: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0e: Link down, check cable.
[Node-02: vifmgr: vifmgr.port.ifgrpRemovePort:notice]: Port e0e, node Node-02 has been removed from ifgrp a0b.
[Node-02: mgmt_port_link_status_poll: netif.linkUp:info]: Ethernet e0e: Link up.
[Node-02: vifmgr: vifmgr.portup:notice]: A link up event was received on node Node-02, port e0e.

  • 检查 IFGRPS.XML  我们看到端口报告关闭
Node: Node-02
Interface Group Name: a0a
Distribution Function: ip
       Create Policy: multimode_lacp
         MAC Address: xx.xx.xx.xx.xx.xx
  Port Participation: none
       Network Ports: e0c, e0d
            Up Ports: -
          Down Ports: e0c, e0d
  • 通过接收检查接口上检测到的 IFSTAT -A CRC 错误 

-- interface  e0d  (124 days, 19 hours, 55 minutes, 20 seconds) --

RECEIVE
 Total frames:     1352k | Frames/second:       0  | Total bytes:       258m
 Bytes/second:        0  | Total errors:     5072  | Errors/minute:       0
 Total discards:      0  | Discards/minute:     0  | Multi/broadcast:  2032k
 Non-primary u/c:     0  | CRC errors:        485  | Runt frames:        26

 -- interface  e0e  (124 days, 19 hours, 55 minutes, 25 seconds) --

RECEIVE
 Total frames:      839k | Frames/second:       0  | Total bytes:       248m
 Bytes/second:        0  | Total errors:     4472  | Errors/minute:       0
 Total discards:      0  | Discards/minute:     0  | Multi/broadcast:   601k
 Non-primary u/c:     0  | CRC errors:        194  | Runt frames:        32

  • 更换文件管理器 SFP 和电缆会产生相同的输出
  • 执行环回测试会使端口启动,表明文件管理器硬件正常
 
 Node: Node-02
Interface Group Name: a0a
Distribution Function: ip
       Create Policy: multimode_lacp
         MAC Address: xx.xx.xx.xx.xx.xx
  Port Participation: none
       Network Ports: e0c, e0d
            Up Ports: e0c, e0d
          Down Ports: -

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.