适用场景

  • FAS8300
  • FAS8700
  • ONTAP   9.15.1P7
  • BMC 13.11P1

问题描述

  • EMS 事件报告多个警报,表明 NVRAM 电池电量严重不足,可能导致系统在 24 小时内停止运行。
ALERT monitor.shutdown.nvramLowBattery.pending: NVRAM battery is dangerously low. Halting system in 24 hours. Replace the battery immediately!
ALERT callhome.battery.low: Call home for BATTERY_LOW.
EMERGENCY monitor.nvramLowBattery: NVRAM battery is dangerously low.
ERROR nvmem.battery.capLowWarn: The NVMEM battery capacity is below normal (4 cycles).
ALERT monitor.shutdown.nvramLowBattery.pending:  NVRAM battery is dangerously low. Halting system in 23 hours. Replace the battery immediately!
  • NVMEM 电池容量低于正常水平(4 个循环)。
::*> system node environment sensors show -name "Bat Curr"|"Bat Dstg Cycles"
Node Sensor          State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
Node01
   Bat Curr        normal
                     0 mA      -     -   1225   1475
   Bat Dstg Cycles     warn-low
                    4 cycles   2     5     -     -
Node02
   Bat Curr        normal
                     0 mA      -     -   1225   1475
   Bat Dstg Cycles     normal
                    14 cycles    2     5     -     -

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.