跳转到主内容

插槽11中的NVDIMM失败、并在节点启动时显示错误nvdimm.nvmem.initfault:FAULT"

Views:
20
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

适用场景

  • AFF A800、AFF C800、ASA A800、ASA C800
  • AFF A400、AFF C400、ASA A400、ASA C400
  • FAS8300、FAS8700
  • ONTAP 9

问题描述

  • 节点无法启动、并显示以下错误:
[nvdimm.nvmem.initfail:FAULT]:NVMEM subsystem initialization failed because NVDIMM device in slot-11   
failed to configure energy source
  • 在 ONTAP升级过程中、节点重新启动后会出现以下崩溃:

**********************************************************************
NVMEM subsystem failed initialization or configuration check To prevent NVMEM data loss, halt the system.
Set bootarg.init.battery_override can ignore this error and continue to boot.
**********************************************************************

PANIC : System is going to shutdown because NVMEM subsystem failed initialization or configuration check.
version: 9.10.1P4: Mon May 9 18:11:44 EDT 2022

  • 节点上报告了以下事件:

[nvdimm.nvmem.initfail:FAULT]:NVMEM subsystem initialization failed because NVDIMM device in slot-23 lost persistence due to SDRAM not in self-refresh mode , andNVDIMM HARDWARE error.. To prevent NVMEM data loss, halt the system.
[nvdimm.nvmem.destage.failure:ALERT]:NVMEM subsystem failed to copy nonvolatile data to flash memory on NVDIMM device because SDRAM is not in self-refresh mode, and because of a hardware error..

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.