由于重置监视程序、NSM模块已重新启动
适用场景
- ONTAP 9
- NVMe 磁盘架
问题描述
- 使用最新固件的磁盘架的两个NSM之一 已重新启动
Mon Oct 09 18:09:50 -0400 [NODE1: dsa_sfu: sfu.rebootRequest:info]: Issuing a request to reboot disk shelf 0x.shelf0 module B.
- NSM在没有任何干预的情况下恢复正常。
Mon Oct 09 18:16:06 -0400 [NODE1: dsa_disc: ses.mismatch.fw.version:error]: The disk shelf modules on disk shelf 0x.0 are running two different firmware versions. Disk shelf module A is running 0210, and disk shelf module B is running .
- 从 触发的 诊断 ASUP中,我们可以看到同时发生了监视程序重置
来自AutoSupport的SHELFLOG-NSM-master.GZ
Shelflog start time: Sat Sep 9 14:55:31 GMT 2023
Controller Id: 000000000
Channel: 0x Shelf: 0 Module type: NSM100 Firmware rev: 0210
Shelf product id: NS224NSM100
Shelf Serial Number: SHFGxxxxxxxxx39
Module B Serial Number: 041xxxxxxxx2
Log ID: SHFGxxxxxxxxx39_B_0
Timestamp: Sat Oct 7 11:57:37 EDT 2023
--------------------------------------------------------------
EVENT LOGS
Timestamp Sat Oct 7 15:57:36 2023
Sat Oct 7 15:56:19 2023 ( 0 00:00:50.005); 0200025D; U?; HAL; hal; 02; Hardware watchdog enabled
Sat Oct 7 15:56:19 2023 ( 0 00:00:50.005); 0200025B; U?; HAL; hal; 02; HW watchdog intervals: L1(255), L2(5) rc:0
Sat Oct 7 15:56:19 2023 ( 0 00:00:50.005); 0200025E; U?; HAL; hal; 02; VPD hardware watchdog interval (255)
Sat Oct 7 15:56:19 2023 ( 0 00:00:50.005); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 4-Watchdog reset (regVal:0xC4)