跳转到主内容

由于重置监视程序、NSM模块已重新启动

Views:
3
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009年789276</a>
Last Updated:

适用场景

  • ONTAP 9
  • NVMe 磁盘架

问题描述

  • 使用最新固件的磁盘架的两个NSM之一 已重新启动

Mon Oct 09 18:09:50 -0400 [NODE1: dsa_sfu: sfu.rebootRequest:info]: Issuing a request to reboot disk shelf 0x.shelf0 module B.​​​​​

  • NSM在没有任何干预的情况下恢复正常。

Mon Oct 09 18:16:06 -0400 [NODE1: dsa_disc: ses.mismatch.fw.version:error]: The disk shelf modules on disk shelf 0x.0 are running two different firmware versions. Disk shelf module A is running 0210, and disk shelf module B is running .

  • 从 触发的 诊断 ASUP中,我们可以看到同时发生了监视程序重置

来自AutoSupport的SHELFLOG-NSM-master.GZ 

Shelflog start time: Sat Sep  9 14:55:31 GMT 2023
Controller Id: 000000000
Channel: 0x Shelf: 0 Module type: NSM100 Firmware rev: 0210
Shelf product id: NS224NSM100
Shelf Serial Number: SHFGxxxxxxxxx39
Module B Serial Number: 041xxxxxxxx2
Log ID: SHFGxxxxxxxxx39_B_0
Timestamp: Sat Oct  7 11:57:37 EDT 2023
--------------------------------------------------------------
EVENT LOGS
Timestamp Sat Oct  7 15:57:36 2023
Sat Oct  7 15:56:19 2023 (    0 00:00:50.005); 0200025D; U?; HAL; hal; 02; Hardware watchdog enabled
Sat Oct  7 15:56:19 2023 (    0 00:00:50.005); 0200025B; U?; HAL; hal; 02; HW watchdog intervals: L1(255), L2(5) rc:0
Sat Oct  7 15:56:19 2023 (    0 00:00:50.005); 0200025E; U?; HAL; hal; 02; VPD hardware watchdog interval (255)
Sat Oct  7 15:56:19 2023 (    0 00:00:50.005); 02000093; U?; HAL; hal; 04; Module Reboot: Startup type 4-Watchdog reset (regVal:0xC4)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.