适用场景

  • NS224 驱动器架
  • 具有 0131 固件的 NSM100 模块

问题描述

  • NVMe 磁盘架模块( NSM )报告通过一条路径暂时无法访问
Jan 18, 2022 22:30:48 +0100HA Group Notification (Health Monitor process nchm: NoPathToNSMB_Alert[XXXXXXXXXXXXX]) ALERT
Jan 18, 2022 22:31:17 +0100HA Group Notification (DISK REDUNDANCY FAILED) ERROR
  • EMS 日志显示连接端口已关闭
Tue Jan 18 22:31:11 +0100 [node-01: kernel: netif.linkDown:info]: Ethernet e0d: Link down, check cable.
Tue Jan 18 22:31:11 +0100 [node-01: intr: netif.linkDown:info]: Ethernet e0d-30: Link down, check cable.
  • 系统将显示单路径状态
Cluster::> system node run -node <node name> -command sysconfig -a
 
System Storage Configuration: Single-Path HA
  • 此路径会在短时间后变为可用,而无需任何用户干预
Tue Jan 18 22:31:55 +0100 [node-01: kernel: netif.linkUp:info]: Ethernet e0d: Link up.
Tue Jan 18 22:31:55 +0100 [node-01: intr: netif.linkUp:info]: Ethernet e0d-30: Link up.
Tue Jan 18 22:56:13 +0100 [node-01: dsa_disc: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage
 
System Storage Configuration: Multi-Path HA
  • 在此期间未执行磁盘架固件升级

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.