NS224 磁盘架会暂时断开一条路径上的连接
适用场景
- NS224 驱动器架
- 具有 0131 固件的 NSM100 模块
问题描述
- NVMe 磁盘架模块( NSM )报告通过一条路径暂时无法访问
Jan 18, 2022 22:30:48 +0100HA Group Notification (Health Monitor process nchm: NoPathToNSMB_Alert[XXXXXXXXXXXXX]) ALERT
Jan 18, 2022 22:31:17 +0100HA Group Notification (DISK REDUNDANCY FAILED) ERROR
- EMS 日志显示连接端口已关闭
Tue Jan 18 22:31:11 +0100 [node-01: kernel: netif.linkDown:info]: Ethernet e0d: Link down, check cable.
Tue Jan 18 22:31:11 +0100 [node-01: intr: netif.linkDown:info]: Ethernet e0d-30: Link down, check cable.
- 系统将显示单路径状态
Cluster::> system node run -node <node name> -command sysconfig -a
System Storage Configuration: Single-Path HA
- 此路径会在短时间后变为可用,而无需任何用户干预
Tue Jan 18 22:31:55 +0100 [node-01: kernel: netif.linkUp:info]: Ethernet e0d: Link up.
Tue Jan 18 22:31:55 +0100 [node-01: intr: netif.linkUp:info]: Ethernet e0d-30: Link up.
Tue Jan 18 22:56:13 +0100 [node-01: dsa_disc: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage
System Storage Configuration: Multi-Path HA
- 在此期间未执行磁盘架固件升级