NS224磁盘架温度过高88 C (190 F)错误
适用场景
- ONTAP 9
- NS224 磁盘架
- NSM100
问题描述
- 对受影响的HA对触发间歇性温度警报。
- 物理检查确认硬件上没有琥珀色LED。
- 此时将触发以下事件:
HA Group Notification from Node06 (SHELF OVER TEMPERATURE 88 C (190 F)) ERROR
HA Group Notification from Node05 (SHELF_FAULT) ERROR
dsa_worker3: ses.status.temperatureError:error]: NS224NSM100 (S/N SHJGD2246900158) shelf 0 on channel 0x temperature error for Temperature sensor 14: critical status; overtemperature failure. Current temperature: 88 C (190 F). This element is on the unknown location.
dsa_worker3: ses.status.temperatureError:error]: NS224NSM100 (S/N SHJGD2246900158) shelf 0 on channel 0x temperature error for Temperature sensor 15: critical status; overtemperature failure. Current temperature: 88 C (190 F). This element is on the unknown location.
Channel: 0x
Shelf: 0
SES device path: local access: 0x.0.0.99
Module type: NSM100; monitoring is active
Shelf status: critical condition
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17; with error: 14, 15
[14] 91 C (195 F) Overtemperature failure!
[15] 91 C (195 F) Overtemperature failure!