在更换没有缺失驱动器的磁盘后、出现NS224磁盘冗余失败错误
适用场景
- NS224磁盘架正在运行固件。2.10
- 发生故障后更换磁盘
问题描述
- 磁盘出现故障并已更换
- 更换磁盘后、AutoSupport会发送消息、其中包含:
[...: dsa_disc: callhome.dsk.redun.fault:debug]: Call home for DISK REDUNDANCY FAILED
- 报告NSM100模块问题描述、但已清除
[node_name-01: mgwd: callhome.hm.alert.major:debug]: Call home for Health Monitor process schm: NoPathFromSwitchToNSM_Alert[1.1:A].
Alert ID NoPathFromSwitchToNSM_Alert
Description Storage shelf 1.1 module A is not connected to storage switches.
Corrective Actions Connect shelf 1.1 module A to two storage switches, following the guide applicable to your shelf.
Possible Effect Access to shelf 1.1 can be lost with a single shelf module failure.
[node_name-01: schmd: hm.alert.cleared:debug]: Alert Id = NoPathFromSwitchToNSM_Alert , Alerting Resource = 1.2:A cleared by monitor system-connect
- 系统存储从四路径过渡到混合路径HA
[node_name-01: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
[node_name-02: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
- 更换的磁盘 未报告通过另一个NSM100模块的路径/连接。
- 已发现路径
node_name-02:e4b.01.1.5
node_name-02:e4a.01.0.5
node_name-01:e4b.01.1.5
node_name-01:e4a.01.0.5
-
- 缺少路径:
node_name-01:e4a.01.2.5
node_name-01:e4b.01.3.5
node_name-02:e4b.01.3.5
node_name-02:e4a.01.2.5
- 在任何磁盘架组件(包括磁盘)中未找到任何erros。
- 更换/重新安装磁盘后、问题描述仍会保留
- 在NSM100 A模块重新安装后、问题描述仍保持不变
- 问题描述在两个NSM100模块之后仍然存在
'soft reboot'