多个传感器报告 NS224 磁盘架上的不可用状态
适用场景
NS224 磁盘架
问题描述
- 磁盘架上的多个传感器报告为不可用或不适用
cluster1::> system node run -node <nodename> -command environment status
Shelf status: normal condition
SES Configuration, shelf 0:
logical identifier=XXXXXXXXXXXXXXXXXX
vendor identification=NETAPP
product identification=NS224NSM100
product revision level=0131
Vendor-specific information:
Product Serial Number: XXXXXXXXXXXXXXX
Power Supply installed element list: 2; with error: none
Power Supply information by element:
[1] Serial number: <N/A> Part number: <N/A>
Type: <N/A>
Firmware version: <N/A>
Swaps: 0
[2] Serial number: XXXXXXXXXXXXXX Part number: DPS-1600AB-18 C
Type: 00
Firmware version: 00.15.04
Swaps: 0
Voltage Sensor installed element list: 2; with error: none
Shelf voltage by element:
[1] Unavailable
[2] 12.01 Volts Normal voltage range
Current Sensor installed element list: 2; with error: none
Shelf current by element:
[1] Unavailable
[2] 18980 mA Normal current range
Cooling Unit installed element list: 11, 12, 13, 14, 15, 16, 17, 18, 19, 20; with error: none
Cooling Units by element:
[1] Unavailable
[2] Unavailable
[3] Unavailable
[4] Unavailable
[5] Unavailable
[6] Unavailable
[7] Unavailable
[8] Unavailable
[9] Unavailable
[10] Unavailable
[11] 6780 RPM
[12] 6440 RPM
[13] 6400 RPM
[14] 6510 RPM
[15] 6480 RPM
[16] 8270 RPM
[17] 7820 RPM
[18] 7950 RPM
[19] 8150 RPM
[20] 8140 RPM
ES Electronics information by element:
[1] Serial number: <N/A> Part number: <N/A>
CPLD version: <N/A> Swaps: 0
[2] Serial number: XXXXXXXXXXXX Part number: 111-04256+B4
CPLD version: 1F Swaps: 0
- 所有受影响的传感器都位于同一模块上。