跳转到主内容

出现SCSI.cmd.abordedByHost:错误警报后出现多个故障驱动器

Views:
52
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用场景

  • FAS8700 

问题描述

  • 针对驱动器报告了多个SCSI错误

[scsi.cmd.abortedByHost:error]: Device 0a.01.22: Command aborted by host adapter: HA status 0x0x4: cdb 0x28:56161ba8:0050. (Additional EMS parameters: deviceType="Disk" disk_information="")
[scsi.cmd.abortedByHost:error]: Device 0a.01.18: Command aborted by host adapter: HA status 0x0x4: cdb 0x28:6f9be9b0:0008. (Additional EMS parameters: deviceType="Disk" disk_information="")
[scsi.cmd.retrySuccess:debug]: Device 0a.01.18: request successful after retry #1: cdb 0x28:6f9be9b0:0008. (Additional EMS parameters: deviceType="Disk" freeRetryCount="0" dTime="8035")
[scsi.cmd.abortedByHost:error]: Device 0a.01.22: Command aborted by host adapter: HA status 0x0x4: cdb 0x28:5615abf8:0200. (Additional EMS parameters: deviceType="Disk" disk_information="")
[scsi.cmd.retrySuccess:debug]: Device 0a.01.22: request successful after retry #1: cdb 0x28:56161ba8:0050. (Additional EMS parameters: deviceType="Disk" freeRetryCount="0" dTime="8343")
[scsi.cmd.retrySuccess:debug]: Device 0a.01.22: request successful after retry #1: cdb 0x28:5615abf8:0200. (Additional EMS parameters: deviceType="Disk" freeRetryCount="0" dTime="8350")
[scsi.cmd.underrun:error]: Device 0a.01.4: Received a data underrun: cdb 0x28:79143a08:01a8. Not all the data was received. Possible transmission error. I/O will be retried. (Additional EMS parameters: deviceType="Disk" disk_information="")

  • 收到错误后、驱动器开始出现故障
[raid.disk.predictiveFailure:error]: Disk 0a.01.6 Shelf 1 Bay 6 [NETAPP   X357_KPM6V3T8ATE NA50] S/N [XXXXXXXXXXXXX] UID [58CE38EE:222E26AC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] reported a predictive failure and it is prefailed; it will be copied to a spare and failed (Additional EMS parameters: shelf="1" bay="6" vendor="NETAPP " model="X357_KPM6V3T8ATE" firmware_revision="NA50" serialno="XXXXXXXXXXXXX" disk_type="5" disk_rpm="N/A" carrier="" site="Local")
  • 由于多磁盘崩溃、节点崩溃
  • 重新启动后、我们发现多个驱动器无法初始化
[Node-01:disk.init.failureBytes:error]: Failed disk 0d.01.8 detected during disk initialization.
[Node-01:disk.init.failureBytes:error]: Failed disk 0d.01.22 detected during disk initialization.
[Node-01:disk.init.failureBytes:error]: Failed disk 0d.01.4 detected during disk initialization.
[Node-01:disk.init.failureBytes:error]: Failed disk 0d.01.6 detected during disk initialization.
  • 由于根卷的驱动器出现故障、节点无法启动至ONTAP

[raid.assim.rg.missingChild:debug]: Aggregate Aggr01, rgobj_verify: RAID object 0 has only 6 valid children, expected 11.
[raid.assim.plex.missingChild:debug]: Aggregate Aggr01, plexobj_verify: Plex 0 only has 0 working RAID groups (1 total) and is being taken offline
[raid.assim.mirror.noChild:debug]: Aggregate Aggr01, mirrorobj_verify: No operable plexes found.
[raid.assim.tree.noRootVol:error]: No usable root volume found!

  • 在维护模式下、我们可以看到aggr status -r输出、其中显示了发生故障/缺失的驱动器

Aggregate aggr01 (failed, raid_dp, partial, fast zeroed) (block checksums)
  Plex /aggr01/plex0 (offline, failed, inactive)
    RAID group /aggr01/plex0/rg0 (partial, block checksums)

      RAID Disk Device          HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------          ------------- ---- ---- ---- ----- --------------    --------------
      dparity   0d.01.18P2      0d    1   18  SA:B   0   SSD   N/A 1799343/3685054464 1799351/3685070848 (fast zeroed)
      parity    0a.01.1P2       0a    1   1   SA:A   0   SSD   N/A 1799343/3685054464 1799351/3685070848 (fast zeroed)
      data      FAILED                  N/A                        1799343/ -
      data      0a.01.3P2       0a    1   3   SA:A   0   SSD   N/A 1799343/3685054464 1799351/3685070848 (fast zeroed)
      data      FAILED                  N/A                        1799343/ -
      data      0a.01.23P2      0a    1   23  SA:A   0   SSD   N/A 1799343/3685054464 1799351/3685070848 (fast zeroed)
      data      FAILED                  N/A                        1799343/ -
      data      FAILED                  N/A                        1799343/ -
      data      0a.01.21P2      0a    1   21  SA:A   0   SSD   N/A 1799343/3685054464 1799351/3685070848 (fast zeroed)
      data      FAILED                  N/A                        1799343/ -
      data      0a.01.5P2       0a    1   5   SA:A   0   SSD   N/A 1799343/3685054464 1799351/3685070848 (fast zeroed)
      Raid group is missing 5 disks.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.